{"title":"Lincoln Pipeliner Welding Rods","description":"\u003cp style=\"font-size:0.9em;margin-bottom:12px;\"\u003e← \u003ca href=\"\/collections\/stick-welding-electrodes-rods\" title=\"All Stick Electrodes \u0026amp; Welding Rods\"\u003eAll Stick Electrodes \u0026amp; Welding Rods\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eLincoln Pipeliner Welding Rods — Pipeline SMAW Electrodes\u003c\/h2\u003e\n\u003cp\u003eLincoln Pipeliner welding rods cover the pipeline SMAW electrode progression for position pipe welding under API 1104. Each product is a cellulosic stick electrode or low-hydrogen grade engineered for the welding of cross country and in plant pipe: cellulosic grades (7P) for root and hot pass; E8010-P1 grades (8P) for cap pass work on X60–X70 line pipe. Browse by diameter below or \u003ca href=\"\/pages\/pipe-welding\"\u003eread the pipe welding guide\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch2\u003ePipeliner 7P+ — Root Pass (E7010-P1)\u003c\/h2\u003e\n\u003cp\u003ePipeliner 7P+ E7010-P1 delivers vertical down welding on DC− with deep penetration and a clean visible weld puddle through mill scale. Q2 lot controlled chemistry and SSC-rated deposit. Min: 90 A at 1\/8 in diameter; 130 A at 5\/32 in diameter. Standard rod for the welding of cross country transmission and gathering lines. View product page for full datasheet. Add to cart.\u003c\/p\u003e\n\n\u003ch3\u003eLincoln Electric Pipeliner 7P+ E7010-P1 — 1 8 x 14 in, 50 lb\u003c\/h3\u003e\n\u003cp\u003eRoot and hot pass. 1\/8 in diameter. 50 lb easy-open can. Product SKU ED031611. Add to cart.\u003c\/p\u003e\n\n\u003ch3\u003eLincoln Electric Pipeliner 7P+ E7010-P1 — 5 32 x 14 in (3.2 mm), 50 lb\u003c\/h3\u003e\n\u003cp\u003eHeavy-wall root pass. 5\/32 in diameter (3.2 mm). 50 lb. Designed for vertical down welding. Clean visible weld puddle. Add to cart.\u003c\/p\u003e\n\n\u003ch2\u003eLincoln Electric Pipeliner 8P+ — E8010-P1 Grade\u003c\/h2\u003e\n\u003cp\u003ePipeliner 8P+ E8010-P1 delivers the mechanical properties high productivity position pipe welding demands on X60–X70. Charpy V-notch impact exceeds API 1104 min at −20 °F; ft lbs values meet X65\/X70 min. Q2 lot controlled chemistry. High productivity in vertical down SMAW. Email for volume pricing.\u003c\/p\u003e\n\n\u003ch3\u003eLincoln Electric Pipeliner 8P+ E8010-P1 — 1 8 x 14 in, 50 lb\u003c\/h3\u003e\n\u003cp\u003eDiameter: 1\/8 in. 50 lb. Superior puddle control and clean visible weld puddle. Add to cart.\u003c\/p\u003e\n\n\u003ch3\u003eLincoln Electric Pipeliner 8P+ E8010-P1 — 5 32 x 14 in (3.2 mm), 50 lb\u003c\/h3\u003e\n\u003cp\u003eHigher-deposition grade. 5\/32 in diameter (3.2 mm). 50 lb. Designed for vertical down fill pass work. Charpy V-notch tested. Ft lbs per API 1104 Annex B. Add to cart.\u003c\/p\u003e\n\n\u003ch3\u003eLincoln Electric Pipeliner 8P+ E8010-P1 — 5 32 x 14 in (3.2 mm), 50 lb — SSC Rated\u003c\/h3\u003e\n\u003cp\u003eSour-service grade. 5\/32 in (3.2 mm). 50 lb. SSC rated. Position pipe welding. Add to cart.\u003c\/p\u003e\n\n\u003ch3\u003eLincoln Electric Pipeliner 8P+ E8010-P1 — 1 8 x 14 in, 50 lb — Deep Penetration\u003c\/h3\u003e\n\u003cp\u003eDeep penetration grade. 1\/8 in diameter. 50 lb. Q2 lot controlled chemistry. Product specification: E8010 P1. Add to cart.\u003c\/p\u003e\n\n\u003ch3\u003eLincoln Electric Pipeliner 8P+ E8010-P1 — 3\/16 x 14 in, 50 lb\u003c\/h3\u003e\n\u003cp\u003eThick-wall grade. 3\/16 in diameter. 50 lb. E8010 P1. Position pipe welding. Add to cart.\u003c\/p\u003e\n\n\u003ch2\u003ePipeliner Arc 80 — E8010-G Low-Alloy Cap Grade\u003c\/h2\u003e\n\u003cp\u003ePipeliner Arc 80 E8010-G is purpose-built for cap pass work on high-grade API line pipe where enhanced low-alloy mechanical properties are specified. High productivity in vertical down SMAW. Charpy V-notch ft lbs values exceed API 1104 requirements for X70 and above. Q2 lot controlled chemistry. SSC rated for country and in plant pipe applications. Confirm classification per WPS before production. View product for full spec.\u003c\/p\u003e\n\n\u003ch3\u003ePipeliner Arc 80 E8010-G — 1 8 x 14 in, 50 lb\u003c\/h3\u003e\n\u003cp\u003eDiameter: 1\/8 in. 50 lb. Superior puddle control. Add to cart.\u003c\/p\u003e\n\n\u003ch3\u003ePipeliner Arc 80 E8010-G — 5 32 x 14 in (3.2 mm), 50 lb\u003c\/h3\u003e\n\u003cp\u003e5\/32 in (3.2 mm). 50 lb. Charpy V-notch tested. Deep penetration on cap pass. Add to cart.\u003c\/p\u003e\n\n\u003ch2\u003eWhen to Choose Pipeliner Welding Rods\u003c\/h2\u003e\n\u003cp\u003eLincoln Pipeliner electrodes are engineered specifically for API 1104-governed pipeline work. Selecting the correct product for each pass type and pipe grade is critical to meeting mechanical property requirements and avoiding rework. The following use-cases show where each Pipeliner grade is the specified choice:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCross-country transmission pipelines (X60–X70):\u003c\/strong\u003e Pipeliner 8P+ E8010-P1 is specified by most major pipeline contractors for fill and cap passes on high-grade line pipe. The high productivity in vertical down SMAW translates directly into reduced weld time per joint — a significant cost factor on long cross country spreads. Q2 lot controlled chemistry ensures heat-to-heat repeatability across the entire project's weld metal records.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoot and hot pass on heavy-wall pipe:\u003c\/strong\u003e Pipeliner 7P+ E7010-P1 at 5\/32 in diameter is the standard choice for root pass work on wall thicknesses above 0.500 in. Deep penetration through mill scale and clean visible weld puddle visibility give welders clear arc control without grinding between passes.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSour service gathering lines (H₂S environments):\u003c\/strong\u003e The SSC-rated variant of Pipeliner 8P+ is required when welding of cross country or in plant pipe operating in wet H₂S service. SSC compliance under NACE MR0175 limits weld metal hardness to HRC 22 max — Pipeliner 8P+ SSC is lot-tested to meet this threshold.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIn-plant pipe spooling:\u003c\/strong\u003e For shop fabrication of process piping spools under API 1104 or ASME B31.3, Pipeliner Arc 80 E8010-G provides the low-alloy mechanical properties needed for X70 and higher-grade fittings without switching to submerged arc processes.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTie-ins and hot taps on live lines:\u003c\/strong\u003e The deep penetration and fast-freezing cellulosic flux of Pipeliner 7P+ allow root passes in constrained access positions where the welder cannot access the back side of the joint. The clean visible weld puddle through mill scale is a key advantage on in-service line repairs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003ePipeliner vs Other Lincoln SMAW Electrodes\u003c\/h2\u003e\n\u003cp\u003eUnderstanding how Pipeliner grades compare to standard Lincoln stick electrodes prevents misspecification on pipeline WPS documents:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePipeliner 7P+ (E7010-P1) vs Fleetweld 5P+ (E6010):\u003c\/strong\u003e Both are cellulosic DC− electrodes with deep penetration. The key difference is classification: E7010-P1 meets API 1104 mechanical minimums for pipeline root passes (70 ksi tensile, Charpy V-notch at −20 °F); E6010 does not carry the P1 suffix and may not satisfy pipeline WPS requirements on higher-grade pipe.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePipeliner 8P+ (E8010-P1) vs Fleetweld 47 (E7018):\u003c\/strong\u003e E7018 is a low-hydrogen electrode for structural work — it produces a slow-freezing, iron-powder flux deposit unsuited to vertical down position pipe welding. Pipeliner 8P+ is cellulosic, freeze-fast, and designed for the vertical down travel speed that pipeline welding demands.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePipeliner Arc 80 (E8010-G) vs Pipeliner 8P+ (E8010-P1):\u003c\/strong\u003e Arc 80 adds enhanced low-alloy chemistry (Ni-Mo additions) to improve low-temperature Charpy V-notch performance above what standard E8010-P1 requires. Use Arc 80 when the WPS specifies minimum 20 ft lbs at −40 °F or when base metal is X70 or higher grade.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePipeliner 7P+ vs Shield-Arc HYP (E7010-G):\u003c\/strong\u003e Shield-Arc HYP is a pipeline-suitable E7010-G grade but does not carry the P1 lot-chemistry certification. For Q2 lot-certified cross country work where chemical traceability is required by the pipeline owner's welding specification, Pipeliner 7P+ is the correct choice.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eStorage and Re-baking — Pipeliner Cellulosic Electrodes\u003c\/h2\u003e\n\u003cp\u003eCellulosic electrodes like Pipeliner 7P+ and 8P+ behave very differently from low-hydrogen rods in storage — they actually require a controlled level of moisture in the flux coating to perform correctly:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eStore Pipeliner cellulosic rods at ambient temperature (not in a hot rod oven) in their original sealed containers. Excess drying destroys the cellulose in the flux, causing violent arc behavior and excessive spatter.\u003c\/li\u003e\n  \u003cli\u003eIf rods arrive damp (visible moisture on the flux), condition at 180–220°F (80–104°C) for 30–60 minutes only — do not exceed these temperatures.\u003c\/li\u003e\n  \u003cli\u003eFor Pipeliner Arc 80 E8010-G (low-alloy grade), follow Lincoln Electric's SDS storage guidance; this grade has tighter moisture tolerance than standard cellulosic rods.\u003c\/li\u003e\n  \u003cli\u003eDo not mix cellulosic and low-hydrogen rods in the same oven. Low-hydrogen rebake temperatures (500–800°F) will ruin cellulosic flux coatings.\u003c\/li\u003e\n  \u003cli\u003eDate-stamp each opened can and track exposure time per your welding quality plan to support API 1104 documentation requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eSafety and PPE — Pipeliner SMAW Pipeline Welding\u003c\/h2\u003e\n\u003cp\u003ePipeline SMAW with cellulosic electrodes generates high-intensity UV radiation and significant fume volumes. Required PPE for Pipeliner operations:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eANSI-rated welding helmet, minimum shade 10 for standard amperage ranges; shade 11–12 for 5\/32 in at high deposition.\u003c\/li\u003e\n  \u003cli\u003eFlame-resistant (FR) clothing rated to NFPA 2112 — mandatory on pipeline right-of-way operations where open-trench ignition risk exists.\u003c\/li\u003e\n  \u003cli\u003eApproved respiratory protection (half-face APF 10 minimum) when welding in ditches or confined pipe sections where natural ventilation is inadequate.\u003c\/li\u003e\n  \u003cli\u003eReview SDS for Mn, Ni, and Mo exposure thresholds applicable to the Pipeliner Arc 80 low-alloy grade.\u003c\/li\u003e\n  \u003cli\u003eCalifornia Prop 65: cancer and reproductive harm — consult SDS before use.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eRelated Resources\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"\/pages\/pipe-welding\"\u003ePipe Welding Guide — electrode selection by pass and position\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/collections\/lincoln-stick-welders\"\u003eLincoln Stick Welders for pipeline SMAW\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/collections\/stick-welding-electrodes-rods\"\u003eStick Welding Electrodes — full SMAW electrode range\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/collections\/welder-trailer\"\u003eWelder Trailers for pipeline spreads\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","products":[{"product_id":"lincoln-pipeliner-stick-smaw-welding-rod","title":"Lincoln Pipeliner Arc 80 E8010-G Stick Welding Rod","description":"\u003c!-- Stick Lane A | handle: lincoln-pipeliner-stick-smaw-welding-rod | 2026-06-16 --\u003e\n\u003csection class=\"pdp-overview\"\u003e\n  \u003ch2\u003eLincoln Pipeliner Arc 80 E8010-G — Overview\u003c\/h2\u003e\n  \u003cp\u003e\u003cstrong\u003eLincoln Pipeliner Arc 80\u003c\/strong\u003e is an AWS A5.5\/A5.5M \u003cstrong\u003eE8010-G\u003c\/strong\u003e cellulosic SMAW electrode engineered for demanding cross-country pipeline welding where higher-strength line pipe (X60, X65) requires matching weld metal above the 60 ksi range. As a member of Lincoln's legendary \u003cstrong\u003ePipeliner family\u003c\/strong\u003e, Arc 80 delivers the same fast-freeze, all-position cellulosic arc performance that pipeline welders depend on for open-root, hot pass, and fill on high-strength pipe — combined with 80 ksi minimum tensile strength to meet code requirements for higher-grade steel. \u003cstrong\u003eDC+ (DCEP) only.\u003c\/strong\u003e WeldingMart is an authorized Lincoln Electric distributor with factory-fresh Pipeliner stock.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"pdp-specs\"\u003e\n  \u003ch2\u003eSpecifications\u003c\/h2\u003e\n  \u003ctable class=\"grade-spec-table\"\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n\u003cth\u003eAWS classification\u003c\/th\u003e\n\u003ctd\u003eAWS A5.5\/A5.5M E8010-G\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth\u003eCoating type\u003c\/th\u003e\n\u003ctd\u003eCellulosic (high-cellulose sodium)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth\u003ePolarity\u003c\/th\u003e\n\u003ctd\u003eDC+ (DCEP) only\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth\u003eWelding positions\u003c\/th\u003e\n\u003ctd\u003eAll positions: 1G, 2G, 3G, 4G (flat, horizontal, vertical, overhead)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth\u003eMinimum tensile strength\u003c\/th\u003e\n\u003ctd\u003e80,000 psi (551 MPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth\u003eMinimum yield strength\u003c\/th\u003e\n\u003ctd\u003e68,000 psi (469 MPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth\u003eElongation\u003c\/th\u003e\n\u003ctd\u003e19% minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth\u003eTypical current range\u003c\/th\u003e\n\u003ctd\u003e3\/32 in: 60–100 A | 1\/8 in: 90–140 A | 5\/32 in: 120–180 A | 3\/16 in: 150–220 A\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth\u003eAvailable diameters\u003c\/th\u003e\n\u003ctd\u003e3\/32, 1\/8, 5\/32, 3\/16 in\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eLincoln Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth\u003eStandards compliance\u003c\/th\u003e\n\u003ctd\u003eAWS A5.5\/A5.5M; API 1104 pre-qualified procedures\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"pdp-applications\"\u003e\n  \u003ch2\u003eApplications \u0026amp; Industries\u003c\/h2\u003e\n  \u003cp\u003ePipeliner Arc 80 is the go-to choice for high-strength pipeline construction and major maintenance work on higher-grade line pipe:\u003c\/p\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eHigh-strength pipeline:\u003c\/strong\u003e Root pass and hot pass on API 5L X60 and X65 line pipe where 80 ksi minimum weld metal is required by WPS\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCross-country mainline:\u003c\/strong\u003e Proven performance in all-position field welding under API 1104 qualified procedures\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTie-in and repair welds:\u003c\/strong\u003e In-service pipeline repair spools and tie-in applications requiring superior root fusion and strength\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePressure vessel and boiler work:\u003c\/strong\u003e Higher-strength carbon steel pressure vessel fabrication under ASME Section IX qualified procedures\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eStructural high-strength steel:\u003c\/strong\u003e AWS D1.1 applications requiring 80 ksi filler metal matching\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"pdp-technique\"\u003e\n  \u003ch2\u003eProcess Technology — How to Run Pipeliner Arc 80\u003c\/h2\u003e\n  \u003cp\u003ePipeliner Arc 80 shares the running characteristics of all Lincoln Pipeliner cellulosic electrodes — a short, controlled arc, DCEP power only, and proper technique for the welding position:\u003c\/p\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePower source:\u003c\/strong\u003e CC DC+ (DCEP) engine-driven welder or inverter rated for E8010. OCV ≥ 65–70 V recommended for consistent arc starting in all positions.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRoot pass technique:\u003c\/strong\u003e Keyhole technique for open-root butt joints — maintain a small keyhole at the leading edge of the puddle to ensure full root penetration without burn-through.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eHot pass:\u003c\/strong\u003e Immediately follow the root with a hot pass using the same electrode (or Pipeliner 7P+ \/ 8P+ for higher-strength fill). Travel angle 5–10° drag; whip-and-pause for vertical-down root progression per API 1104 procedures.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eArc length:\u003c\/strong\u003e Keep tight — approximately equal to rod diameter. Long arc lengths reduce penetration and increase porosity risk with cellulosic rods.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePreheat:\u003c\/strong\u003e Follow WPS requirements for the base metal carbon equivalent. Higher-strength X60\/X65 pipe typically requires preheat per API 1104.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"pdp-storage\"\u003e\n  \u003ch2\u003eStorage \u0026amp; Handling\u003c\/h2\u003e\n  \u003cp\u003ePipeliner Arc 80 is a cellulosic electrode. Unlike low-hydrogen E7018 or E8018, cellulosic electrodes require ambient moisture in the coating for proper arc stability:\u003c\/p\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDo not oven-dry\u003c\/strong\u003e — baking will destroy the cellulosic coating and degrade arc performance\u003c\/li\u003e\n    \u003cli\u003eStore in original sealed container in a dry, ambient-temperature environment (40–120°F \/ 4–49°C)\u003c\/li\u003e\n    \u003cli\u003eRods that have gotten wet should be air-dried at room temperature only; discard if severely wetted\u003c\/li\u003e\n    \u003cli\u003eKeep sealed packaging until ready for use; reseal partially used cartons promptly\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"pdp-faq\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdl\u003e\n    \u003cdt\u003eWhat is the Pipeliner Arc 80 used for?\u003c\/dt\u003e\n    \u003cdd\u003ePipeliner Arc 80 (E8010-G) is used for open-root and hot pass welding on high-strength pipeline (API 5L X60, X65) and structural applications requiring 80 ksi minimum tensile weld metal. It is the higher-strength complement to Lincoln Pipeliner 5P+ (E6010) for demanding code-critical pipeline construction.\u003c\/dd\u003e\n\n    \u003cdt\u003eWhat is the difference between E8010 and E6010?\u003c\/dt\u003e\n    \u003cdd\u003eBoth are cellulosic DC+ electrodes with fast-freeze all-position performance, but E8010 deposits weld metal with 80 ksi minimum tensile strength versus E6010's 60 ksi. E8010 is used when the base material (X60, X65 line pipe, higher-strength structural steel) requires matching higher-strength filler metal per the applicable welding procedure specification.\u003c\/dd\u003e\n\n    \u003cdt\u003eCan Pipeliner Arc 80 run vertical-down?\u003c\/dt\u003e\n    \u003cdd\u003eYes. Like all Pipeliner cellulosic electrodes, Arc 80 is designed for vertical-down (downhill) progression in pipeline welding — a standard technique for root passes on cross-country pipeline under API 1104 procedures. Push angle 15–20° with short arc and keyhole technique.\u003c\/dd\u003e\n\n    \u003cdt\u003eDoes Lincoln Pipeliner Arc 80 require oven storage?\u003c\/dt\u003e\n    \u003cdd\u003eNo. Pipeliner Arc 80 is a cellulosic electrode and does not require oven storage. Store at ambient temperature in sealed packaging. Do not bake — high-temperature drying used for low-hydrogen electrodes will damage the cellulosic coating.\u003c\/dd\u003e\n\n    \u003cdt\u003eWhat Pipeliner electrode should I use for fill and cap passes?\u003c\/dt\u003e\n    \u003cdd\u003eFor high-strength pipeline with an E8010 root pass, the fill and cap passes are typically run with \u003ca href=\"\/products\/lincoln-pipeliner-8p-stick-smaw-welding-rod\"\u003eLincoln Pipeliner 8P+ (E8010-P1)\u003c\/a\u003e or a low-hydrogen electrode per the WPS. For lower-strength pipe, pair the root with \u003ca href=\"\/products\/lincoln-excalibur-7018-stick-smaw-welding-rod\"\u003eLincoln Excalibur 7018\u003c\/a\u003e fill and cap passes.\u003c\/dd\u003e\n  \u003c\/dl\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"pdp-crosslinks\"\u003e\n  \u003cp\u003e\u003cstrong\u003eShop the full Pipeliner family:\u003c\/strong\u003e \u003ca href=\"\/collections\/stick-welding-electrodes-rods\"\u003eStick Welding Electrodes \u0026amp; Rods\u003c\/a\u003e — or see the \u003ca href=\"\/products\/lincoln-pipeliner-8p-stick-smaw-welding-rod\"\u003eLincoln Pipeliner 8P+ E8010-P1\u003c\/a\u003e for all-Pipeliner fill passes.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What is the Pipeliner Arc 80 used for?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Pipeliner Arc 80 (E8010-G) is used for open-root and hot pass welding on high-strength pipeline (API 5L X60, X65) and structural applications requiring 80 ksi minimum tensile weld metal. It is the higher-strength complement to Lincoln Pipeliner 5P+ (E6010) for demanding code-critical pipeline construction.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What is the difference between E8010 and E6010?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Both are cellulosic DC+ electrodes, but E8010 deposits weld metal with 80 ksi minimum tensile strength versus E6010's 60 ksi. E8010 is used when the base material requires matching higher-strength filler metal per the applicable welding procedure specification.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can Pipeliner Arc 80 run vertical-down?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes. Like all Pipeliner cellulosic electrodes, Arc 80 is designed for vertical-down (downhill) progression in pipeline welding — a standard technique for root passes on cross-country pipeline under API 1104 procedures.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does Lincoln Pipeliner Arc 80 require oven storage?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"No. Pipeliner Arc 80 is a cellulosic electrode and does not require oven storage. Store at ambient temperature in sealed packaging. Do not bake — high-temperature drying used for low-hydrogen electrodes will damage the cellulosic coating.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e\n","brand":"Lincoln Electric","offers":[{"title":"1\/8 in · 50 lb Easy Open Can","offer_id":43639163584663,"sku":"ED037582","price":395.25,"currency_code":"USD","in_stock":true},{"title":"5\/32 in · 50 lb Easy Open Can","offer_id":43638142501015,"sku":"ED034456","price":324.25,"currency_code":"USD","in_stock":true},{"title":"3\/16 in · 50 lb Easy Open Can (ED034458)","offer_id":43638144106647,"sku":"ED034458","price":336.77,"currency_code":"USD","in_stock":true},{"title":"3\/16 in · 50 lb Easy Open Can (ED034457)","offer_id":43638143418519,"sku":"ED034457","price":324.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0628\/7140\/4695\/files\/harris-3530-750-000-wo-gauge-regulator-4000859-harris-1.webp?v=1746640658"},{"product_id":"lincoln-pipeliner-6p-stick-smaw-welding-rod","title":"Lincoln Pipeliner 6P+ E6010 Stick Welding Rod","description":"\u003cp\u003eLincoln Pipeliner 6P+ is the industry-standard E6010 pipeliner welding rod for open-root pipeline welding. Trusted by pipeline contractors for decades, Pipeliner 6P+ delivers the deep-penetrating, fast-freeze arc that pipeline root and hot passes demand — with the tighter chemistry and qualification data required under API 1104 and ASME Section IX cross-country pipeline procedures. When you need a certified E6010 pipeliner welding rod for natural gas, crude oil, or water transmission lines, Pipeliner 6P+ is Lincoln's primary recommendation.\u003c\/p\u003e\n\n\u003ch2\u003eWhat Is the Lincoln Pipeliner 6P+ E6010 Pipeliner Welding Rod?\u003c\/h2\u003e\n\u003cp\u003ePipeliner 6P+ is Lincoln Electric's flagship E6010 electrode engineered specifically for pipeline construction and repair. It classifies under AWS A5.1 E6010 — high-cellulose sodium flux, DCEP-only, all-position — but differs from general-purpose E6010 products like Fleetweld 180 in one critical respect: Lincoln conducts and publishes qualification test data under API 1104 \"Welding of Pipelines and Related Facilities,\" the governing standard for cross-country pipeline welding. This API 1104 qualification documentation allows pipeline contractors to use Pipeliner 6P+ in prequalified or procedure-tested WPS on liquid and gas transmission pipelines without performing full independent electrode qualification tests. The \"6P+\" designation reflects 6-o'clock position capability — the toughest position in a rolled or fixed-position pipe joint. The \"+\" indicates enhanced bead wetting and tie-in characteristics compared to the baseline Pipeliner 6P.\u003c\/p\u003e\n\n\u003ch2\u003eAWS Classification \u0026amp; Pipeline Qualification Data — Pipeliner 6P+\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eProperty\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eAWS Classification\u003c\/td\u003e\n\u003ctd\u003eE6010\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTensile Strength (min.)\u003c\/td\u003e\n\u003ctd\u003e67,000 psi (462 MPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eYield Strength (min.)\u003c\/td\u003e\n\u003ctd\u003e55,000 psi (379 MPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eElongation (min.)\u003c\/td\u003e\n\u003ctd\u003e22%\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eAPI 1104 Status\u003c\/td\u003e\n\u003ctd\u003eQualified — Lincoln maintains published test data\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eASME Section IX F-Number\u003c\/td\u003e\n\u003ctd\u003eF3\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eFlux Type\u003c\/td\u003e\n\u003ctd\u003eHigh-cellulose sodium\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eCurrent\u003c\/td\u003e\n\u003ctd\u003eDCEP only\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePosition\u003c\/td\u003e\n\u003ctd\u003eAll positions including 5G, 6G fixed pipe\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDiameters\u003c\/td\u003e\n\u003ctd\u003e3\/32, 1\/8, 5\/32 in\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003ePipeliner 6P+ is an all-position E6010. On pipeline work, it is typically used for root and hot passes; fill and cap passes are completed with Lincoln Pipeliner LH-D80 (E8018-C2), LH-D90 (E8018-G), or other low-hydrogen electrodes specified by the pipeline WPS. For mainline welding per API 1104, always confirm the applicable WPS and contractor-approved electrode list before substituting brands or products.\u003c\/p\u003e\n\n\u003ch2\u003eBest Applications for Pipeliner 6P+ E6010 Welding Rod\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCross-country natural gas and oil pipeline root and hot passes\u003c\/strong\u003e — the primary use case for which Pipeliner 6P+ is designed and qualified.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWater transmission pipeline welding\u003c\/strong\u003e — API 1104-governed water line construction where open-root cellulosic root passes are specified.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGathering line and flow-line welding\u003c\/strong\u003e — smaller-diameter lines serving production facilities.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePipeline repair and tie-in welds\u003c\/strong\u003e — in-service repair welding where fast-freeze slag and penetrating arc are essential on line pipe with internal gas pressure.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFixed-position (5G, 6G) pipe qualification testing\u003c\/strong\u003e — Pipeliner 6P+ is a standard qualification electrode for pipeline welding performance tests.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStructural root passes on heavy plate\u003c\/strong\u003e — when an E6010 penetrating root pass is specified before filling with low-hydrogen filler.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to Use Pipeliner 6P+ — Amperage, Polarity \u0026amp; Position\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eDiameter\u003c\/th\u003e\n\u003cth\u003eRoot Pass Amperage\u003c\/th\u003e\n\u003cth\u003eHot Pass Amperage\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e3\/32 in (2.4 mm)\u003c\/td\u003e\n\u003ctd\u003e55–80 A\u003c\/td\u003e\n\u003ctd\u003e65–90 A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e1\/8 in (3.2 mm)\u003c\/td\u003e\n\u003ctd\u003e75–110 A\u003c\/td\u003e\n\u003ctd\u003e90–130 A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e5\/32 in (4.0 mm)\u003c\/td\u003e\n\u003ctd\u003e110–150 A\u003c\/td\u003e\n\u003ctd\u003e130–175 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003ePolarity:\u003c\/strong\u003e DCEP only. Inverter-type constant-current machines preferred for pipeline work — they maintain arc stability better than older transformer-rectifier machines under varying arc lengths.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRoot pass:\u003c\/strong\u003e The pipeline root pass with E6010 is the most technically demanding SMAW pass. Key technique points:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cem\u003eRoot face preparation:\u003c\/em\u003e 1\/16 to 3\/32 in root face; 3\/32 in root gap standard for most 1\/8 in electrode root passes.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cem\u003eArc length:\u003c\/em\u003e 1\/2 to 1× core diameter. A slightly longer arc than E7018 allows better puddle visibility.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cem\u003eKeyhole:\u003c\/em\u003e Maintain a visible keyhole ahead of the puddle. Travel speed controls keyhole size.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cem\u003e6 o'clock position:\u003c\/em\u003e This is the hardest point — gravity pulls the puddle. Reduce amperage 5–10 A and shorten the arc as you approach 6 o'clock. Speed up slightly to let the puddle freeze before it drips.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cem\u003eInterpass temperature:\u003c\/em\u003e Follow the WPS for interpass temperature limits. Typically 400–500 °F maximum for carbon steel pipeline work.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eStorage \u0026amp; Handling for E6010 Pipeliner Electrodes\u003c\/h2\u003e\n\u003cp\u003ePipeliner 6P+ is a cellulosic electrode — handling is fundamentally different from low-hydrogen electrodes:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNo oven required and NO oven drying:\u003c\/strong\u003e Never bake Pipeliner 6P+ at E7018 holding temperatures. Over-drying destroys the cellulosic flux mechanism. Use at ambient temperature from the sealed container.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStore in sealed Lincoln containers\u003c\/strong\u003e in a dry area at 40–120 °F. Sealed containers maintain correct moisture balance for years.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAvoid prolonged direct sun and heat:\u003c\/strong\u003e In hot climates, avoid leaving open canisters in direct sun in a truck cab or welding rig where internal temperatures can reach 140 °F+ — this can over-dry the flux.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDiscard wetted electrodes:\u003c\/strong\u003e If electrodes fall in water or are heavily rained on, discard them. Restoration of cellulosic moisture balance is impractical.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHandle canisters gently:\u003c\/strong\u003e Cellulosic flux is brittle; impact cracking of the coating causes arc instability and loss of penetration on the root pass — an unacceptable risk in pipeline work.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eCompatible Base Metals \u0026amp; Joint Types for Pipeline E6010\u003c\/h2\u003e\n\u003cp\u003ePipeliner 6P+ is designed for carbon steel and low-alloy carbon steel pipe in the following grades:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAPI 5L Grade B, X42, X52, X60, X65 (higher grades may require procedure qualification)\u003c\/li\u003e\n  \u003cli\u003eASTM A53 Grade B pipe\u003c\/li\u003e\n  \u003cli\u003eASTM A106 Grade B seamless pipe\u003c\/li\u003e\n  \u003cli\u003eASTM A333 Grade 1, 6 (low-temperature service)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor API 5L X70 and above, consult the pipeline contractor's WPS — the higher yield strength and tighter chemistry of these grades typically require specific filler metal procedure qualification. Joint type for pipeline: single-V groove butt joint with open root and land\/root face. Wall thicknesses typically 0.188–0.750 in for small-to-large diameter mainline pipe.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions — Lincoln Pipeliner 6P+ E6010 Electrode\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between Pipeliner 6P+ and Fleetweld 180?\u003c\/strong\u003e\u003cbr\u003e\nBoth are E6010 high-cellulose sodium electrodes. Pipeliner 6P+ has Lincoln-maintained API 1104 qualification test data that contractors can use in pipeline WPS without independent electrode qualification testing. Fleetweld 180 is a general-purpose E6010 for structural, maintenance, and fabrication work. For API 1104 pipeline work, specify Pipeliner 6P+; for general E6010 applications, Fleetweld 180 is equivalent and often more readily available.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can Pipeliner 6P+ be used for hot passes?\u003c\/strong\u003e\u003cbr\u003e\nYes. Pipeliner 6P+ is used for both root and hot passes in cellulosic all-cellulosic pipeline procedures. Hot pass amperage is 10–20 A higher than the root pass to ensure full tie-in and burn-off of any root-side oxidation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What diameter Pipeliner 6P+ for a 12 in OD x 0.375 in wall root pass?\u003c\/strong\u003e\u003cbr\u003e\n1\/8 in diameter Pipeliner 6P+ at 80–105 A DCEP is standard for a 12 in OD pipe root pass. Many contractors use 3\/32 in at 65–80 A for high-cellulosic root passes on larger-diameter pipe where a narrower bead is preferred for tie-in at 6 o'clock.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does Pipeliner 6P+ qualify for ASME Section IX P1 procedures?\u003c\/strong\u003e\u003cbr\u003e\nYes. As an F3 electrode (ASME Section IX QW-432), Pipeliner 6P+ qualifies for F3 positions in P1 carbon steel procedure qualifications. Confirm the specific WPS for any ASME pressure vessel or boiler application.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Why does my E6010 arc feel harsh and spatter-heavy?\u003c\/strong\u003e\u003cbr\u003e\nCommon causes: (1) amperage too high — reduce 10–15 A; (2) arc length too long — tighten the arc; (3) DCEN polarity accidentally selected — always use DCEP; (4) electrode contaminated or cracked flux — inspect and replace.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I use Pipeliner 6P+ for all passes in a pipeline joint?\u003c\/strong\u003e\u003cbr\u003e\nIn some field procedures and maintenance welding, all cellulosic procedures (root, hot, fill, cap all with E6010) are used. However, most modern mainline pipeline WPS call for E6010 root and hot passes with low-hydrogen (E8010-G, E8018-G, or similar) fill and cap to achieve CTOD toughness requirements on high-grade pipe.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What welder output (OCV) do I need for Pipeliner 6P+?\u003c\/strong\u003e\u003cbr\u003e\nA constant-current DC welder with at least 60 V open-circuit voltage (OCV) is recommended for reliable cellulosic arc starts. Engine-driven welders (Lincoln Ranger, Vantage, SAE series) are standard for pipeline work. Some modern inverters achieve reliable E6010 arc starts at 50–55 V OCV, but 60+ V is preferred.\u003c\/p\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\"@type\": \"Question\", \"name\": \"What is the difference between Pipeliner 6P+ and Fleetweld 180?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Both are E6010 electrodes. Pipeliner 6P+ carries Lincoln's API 1104 qualification data for pipeline WPS. Fleetweld 180 is a general-purpose E6010 for structural and fabrication work.\"}},\n    {\"@type\": \"Question\", \"name\": \"Can Pipeliner 6P+ be used for hot passes?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. Pipeliner 6P+ is used for both root and hot passes. Hot pass amperage is 10-20A higher than root pass.\"}},\n    {\"@type\": \"Question\", \"name\": \"What diameter for a 12 in OD x 0.375 in wall root pass?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"1\/8 in at 80-105A DCEP is standard. Some contractors use 3\/32 in at 65-80A for a narrower bead on large-diameter pipe.\"}},\n    {\"@type\": \"Question\", \"name\": \"Does Pipeliner 6P+ qualify for ASME Section IX P1 procedures?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. Pipeliner 6P+ is F3 group filler per ASME Section IX QW-432, qualifying for P1 carbon steel procedures.\"}},\n    {\"@type\": \"Question\", \"name\": \"Why does my E6010 arc feel harsh and spatter-heavy?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Common causes: amperage too high, arc length too long, wrong polarity (must be DCEP), or cracked\/contaminated flux. Reduce amperage, tighten the arc, verify polarity.\"}},\n    {\"@type\": \"Question\", \"name\": \"Can I use Pipeliner 6P+ for all passes?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"All-cellulosic procedures exist but most modern pipeline WPS use E6010 for root and hot passes, then switch to low-hydrogen filler for fill and cap to achieve CTOD toughness on high-grade pipe.\"}},\n    {\"@type\": \"Question\", \"name\": \"What OCV do I need for Pipeliner 6P+?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"60 V OCV minimum is recommended for reliable cellulosic arc starts. Engine-driven welders are standard for pipeline work.\"}}\n  ]\n}\n\u003c\/script\u003e\n\u003ch2\u003ePipeliner 6P+ API 1104 Qualification \u0026amp; Technical Notes\u003c\/h2\u003e\n\u003cp\u003eThe API 1104 standard, \"Welding of Pipelines and Related Facilities,\" is the governing document for cross-country pipeline construction and repair welding. It specifies procedure qualification requirements, welder performance qualification tests, and inspection standards for liquid and gas transmission pipelines. Lincoln Pipeliner 6P+ is tested and documented to meet API 1104 requirements, giving pipeline contractors the qualification data needed to support their WPS without independent electrode testing. The \"6P+\" designation denotes 6-position capability (5G and 6G fixed-position pipe joints) — the most demanding welding positions in pipeline construction. The open-root butt joint in fixed 5G position (pipe horizontal, cannot be rotated) tests a welder's ability to make a consistent root pass and hot pass as they progress from the 12-o'clock position down through 3, 6, and back up through 9 to 12 o'clock. The 6 o'clock position is universally considered the hardest — the molten puddle is fighting gravity as it tries to drip. Pipeliner 6P+ electrodes are engineered with a flux formulation that supports consistent keyhole control and bead behavior from 12 to 6 o'clock and back. For engineers specifying filler metal in pipeline WPS documents, Lincoln's Pipeliner family product data sheets provide the tensile, impact, and all-weld-metal chemistry data required for WPS qualification record (PQR) documentation under API 1104 Section 5.\u003c\/p\u003e","brand":"Lincoln Electric","offers":[{"title":"3\/32 in · 10 lb Easy Open Can (3-Pack)","offer_id":43638086664343,"sku":"ED032609","price":238.05,"currency_code":"USD","in_stock":true},{"title":"1\/8 in · 10 lb Easy Open Can (3-Pack)","offer_id":43638086697111,"sku":"ED032610","price":238.5,"currency_code":"USD","in_stock":true},{"title":"1\/8 in · 50 lb Easy Open Can","offer_id":43638081454231,"sku":"ED030848","price":320.6,"currency_code":"USD","in_stock":true},{"title":"5\/32 in · 10 lb Easy Open Can (3-Pack)","offer_id":43638087024791,"sku":"ED032611","price":83.7,"currency_code":"USD","in_stock":true},{"title":"5\/32 in · 50 lb Easy Open Can","offer_id":43638082699415,"sku":"ED030849","price":294.39,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0628\/7140\/4695\/files\/lincoln-ed032609-pipeliner-6p-stick-smaw-welding-rod-332-12-in-3-10-lb-easy-open-cans-lincoln-electric.jpg?v=1765594807"},{"product_id":"lincoln-pipeliner-7p-stick-smaw-welding-rod","title":"Lincoln Pipeliner 7P+ E7010-P1 Stick Welding Rod","description":"\u003c!-- Stick Lane A | handle: lincoln-pipeliner-7p-stick-smaw-welding-rod | 2026-06-16 --\u003e\n\u003csection class=\"pdp-overview\"\u003e\n  \u003ch2\u003eLincoln Pipeliner 7P+ E7010-P1 — Overview\u003c\/h2\u003e\n  \u003cp\u003e\u003cstrong\u003eLincoln Pipeliner 7P+\u003c\/strong\u003e is an \u003cstrong\u003eAWS A5.5\/A5.5M E7010-P1\u003c\/strong\u003e cellulosic SMAW electrode from Lincoln's world-renowned Pipeliner series, designed for complete-joint welding on API 5L X52 and X60 line pipe where 70 ksi minimum weld metal strength is required. The -P1 toughness designation confirms the electrode meets supplementary low-temperature Charpy V-notch (CVN) impact requirements as specified in API 1104 and ASME Section IX pipeline procedures. Pipeliner 7P+ delivers the characteristically aggressive, fast-freeze Pipeliner arc — ideal for vertical-down root passes, hot passes, and fill beads in cross-country pipeline construction, tie-in welds, and high-pressure station piping. \u003cstrong\u003eDC+ (DCEP) only.\u003c\/strong\u003e Available at WeldingMart as an authorized Lincoln Electric distributor.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"pdp-specs\"\u003e\n  \u003ch2\u003eSpecifications\u003c\/h2\u003e\n  \u003ctable class=\"grade-spec-table\"\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n\u003cth\u003eAWS classification\u003c\/th\u003e\n\u003ctd\u003eAWS A5.5\/A5.5M E7010-P1\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth\u003eCoating type\u003c\/th\u003e\n\u003ctd\u003eCellulosic (high-cellulose sodium)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth\u003ePolarity\u003c\/th\u003e\n\u003ctd\u003eDC+ (DCEP) only\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth\u003eWelding positions\u003c\/th\u003e\n\u003ctd\u003eAll positions: 1G, 2G, 3G, 4G\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth\u003eMinimum tensile strength\u003c\/th\u003e\n\u003ctd\u003e70,000 psi (483 MPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth\u003eMinimum yield strength\u003c\/th\u003e\n\u003ctd\u003e58,000 psi (400 MPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth\u003eElongation\u003c\/th\u003e\n\u003ctd\u003e22% minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth\u003eCVN impact (-20°F)\u003c\/th\u003e\n\u003ctd\u003eMeets AWS A5.5 -P1 toughness requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth\u003eTypical current range\u003c\/th\u003e\n\u003ctd\u003e3\/32 in: 55–95 A | 1\/8 in: 85–130 A | 5\/32 in: 115–175 A | 3\/16 in: 145–210 A\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth\u003eAvailable diameters\u003c\/th\u003e\n\u003ctd\u003e3\/32, 1\/8, 5\/32, 3\/16 in\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eLincoln Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth\u003eStandards compliance\u003c\/th\u003e\n\u003ctd\u003eAWS A5.5\/A5.5M; API 1104; ASME Section IX\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"pdp-applications\"\u003e\n  \u003ch2\u003eApplications \u0026amp; Industries\u003c\/h2\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eX52 and X60 pipeline construction:\u003c\/strong\u003e Root, hot pass, and fill passes on mid-grade API 5L line pipe under API 1104 procedures requiring enhanced toughness\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCross-country mainline welding:\u003c\/strong\u003e High-speed field welding with the vertical-down progression technique used by pipeline welding contractors\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTie-in and repair:\u003c\/strong\u003e In-service pipeline tie-in welds and repair sections where all-position access and weld quality are critical\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eNatural gas distribution:\u003c\/strong\u003e Medium-pressure gas distribution mains and station piping fabrication\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eStructural applications:\u003c\/strong\u003e AWS D1.1 structural steel where 70 ksi filler metal is required with the cellulosic procedure advantages\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"pdp-technique\"\u003e\n  \u003ch2\u003eProcess Technology — How to Run Pipeliner 7P+\u003c\/h2\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePower source:\u003c\/strong\u003e CC DC+ (DCEP) engine-driven welder or inverter rated for E7010. OCV ≥ 65 V for all-position reliability.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRoot pass:\u003c\/strong\u003e Keyhole technique with short arc. For vertical-down root, push angle 15–20° and controlled speed to maintain the keyhole at the leading edge of the puddle.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eHot pass:\u003c\/strong\u003e Follow the root immediately (while the joint is hot) at slightly higher amperage to clean up root pass irregularities. Travel angle 5–10° push on vertical surfaces.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eFill passes:\u003c\/strong\u003e Stringer or narrow weave. On pipeline bevel geometry, stringer beads maximize fusion at bevel face corners.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eArc length:\u003c\/strong\u003e Maintain very short arc — approximately rod diameter. Never allow a long arc with cellulosic electrodes.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePreheat:\u003c\/strong\u003e Per WPS — typically 50–100°F for X52, 100–150°F for X60 with higher CE heats.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"pdp-storage\"\u003e\n  \u003ch2\u003eStorage \u0026amp; Handling\u003c\/h2\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eNo oven drying\u003c\/strong\u003e — Pipeliner 7P+ is a cellulosic electrode; baking destroys the coating\u003c\/li\u003e\n    \u003cli\u003eStore at ambient temperature in sealed original packaging, protected from moisture\u003c\/li\u003e\n    \u003cli\u003eAir-dry only if rods have been exposed to humidity; discard if severely wetted\u003c\/li\u003e\n    \u003cli\u003eLow-hydrogen storage practices (drying ovens, heated quivers) are for E7018\/E8018 class electrodes — not Pipeliner cellulosic rods\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"pdp-faq\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdl\u003e\n    \u003cdt\u003eWhat is the difference between Pipeliner 7P+ and Pipeliner 5P+?\u003c\/dt\u003e\n    \u003cdd\u003eLincoln Pipeliner 5P+ is an E6010 electrode (60 ksi minimum tensile) for general pipeline and structural root pass welding. Pipeliner 7P+ is an E7010-P1 electrode (70 ksi minimum tensile) with enhanced low-temperature toughness for X52\/X60 pipeline where the WPS requires a minimum 70 ksi filler metal with CVN toughness. Select based on your weld procedure specification's minimum tensile and toughness requirements.\u003c\/dd\u003e\n\n    \u003cdt\u003eWhat pipe grades is Pipeliner 7P+ qualified for?\u003c\/dt\u003e\n    \u003cdd\u003ePipeliner 7P+ (E7010-P1) is commonly used for API 5L Grade X52 and X60 line pipe under API 1104 qualified procedures requiring enhanced toughness (-P1). Confirm your specific WPS tensile and CVN toughness requirements before selecting an electrode grade.\u003c\/dd\u003e\n\n    \u003cdt\u003eCan Pipeliner 7P+ be used for all passes or just the root?\u003c\/dt\u003e\n    \u003cdd\u003ePipeliner 7P+ is designed for complete-joint welding on the appropriate pipe grade — root pass, hot pass, and fill passes can all be made with Pipeliner 7P+ to maintain an all-cellulosic procedure, which some contractors prefer for speed and consistency. Cap passes may be made with 7P+ or an approved low-hydrogen electrode per the WPS.\u003c\/dd\u003e\n\n    \u003cdt\u003eIs Pipeliner 7P+ the same as a 7010 electrode?\u003c\/dt\u003e\n    \u003cdd\u003eYes — the AWS classification for Pipeliner 7P+ is E7010-P1, commonly referred to as \"7010\" in the field. The -P1 suffix adds the pipeline toughness requirement to the base E7010 classification.\u003c\/dd\u003e\n  \u003c\/dl\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"pdp-crosslinks\"\u003e\n  \u003cp\u003e\u003cstrong\u003eFull Pipeliner family:\u003c\/strong\u003e \u003ca href=\"\/collections\/stick-welding-electrodes-rods\"\u003eStick Welding Electrodes \u0026amp; Rods\u003c\/a\u003e — compare with \u003ca href=\"\/products\/lincoln-pipeliner-8p-stick-smaw-welding-rod\"\u003ePipeliner 8P+ E8010-P1\u003c\/a\u003e for X65 pipe or \u003ca href=\"\/products\/lincoln-fleetweld-5p-stick-smaw-welding-rod\"\u003eFleetweld 5P+ E6010\u003c\/a\u003e for standard pipeline root passes.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What is the difference between Pipeliner 7P+ and Pipeliner 5P+?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Pipeliner 5P+ is an E6010 (60 ksi minimum tensile) for general pipeline root pass welding. Pipeliner 7P+ is an E7010-P1 (70 ksi minimum tensile) with enhanced CVN toughness for X52\/X60 pipeline procedures. Select based on your WPS minimum tensile and toughness requirements.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What pipe grades is Pipeliner 7P+ qualified for?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Pipeliner 7P+ (E7010-P1) is commonly used for API 5L Grade X52 and X60 line pipe under API 1104 qualified procedures requiring enhanced toughness. Confirm your specific WPS requirements before selecting an electrode grade.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can Pipeliner 7P+ be used for all passes or just the root?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Pipeliner 7P+ is designed for complete-joint welding — root, hot pass, and fill passes can all be made with 7P+ to maintain an all-cellulosic procedure. Cap passes may be 7P+ or an approved low-hydrogen electrode per the WPS.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e\n","brand":"Lincoln Electric","offers":[{"title":"1\/8 in · 10 lb Easy Open Can (3-Pack)","offer_id":43639137370263,"sku":"ED032612","price":238.32,"currency_code":"USD","in_stock":true},{"title":"1\/8 in · 50 lb Easy Open Can","offer_id":43638093185175,"sku":"ED031611","price":331.75,"currency_code":"USD","in_stock":true},{"title":"5\/32 in · 10 lb Easy Open Can (3-Pack)","offer_id":43639137173655,"sku":"ED032613","price":273.3,"currency_code":"USD","in_stock":true},{"title":"5\/32 in · 50 lb Easy Open Can","offer_id":43638057205911,"sku":"ED031612","price":339.3,"currency_code":"USD","in_stock":true},{"title":"3\/16 in · 10 lb Easy Open Can (3-Pack)","offer_id":43639137206423,"sku":"ED032614","price":283.2,"currency_code":"USD","in_stock":true},{"title":"3\/16 in · 50 lb Easy Open Can","offer_id":43638057992343,"sku":"ED031613","price":336.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0628\/7140\/4695\/files\/lincoln-ed032612-pipeliner-7p-stick-smaw-welding-rod-18-14-in-3-10-lb-easy-open-cans-lincoln-electric-1.jpg?v=1760720032"},{"product_id":"lincoln-pipeliner-8p-stick-smaw-welding-rod","title":"Lincoln Pipeliner 8P+ E8010-P1 Stick Welding Rod","description":"\u003c!-- Stick Lane A | handle: lincoln-pipeliner-8p-stick-smaw-welding-rod | 2026-06-16 --\u003e\n\u003csection class=\"pdp-overview\"\u003e\n  \u003ch2\u003eLincoln Pipeliner 8P+ E8010-P1 — Overview\u003c\/h2\u003e\n  \u003cp\u003e\u003cstrong\u003eLincoln Pipeliner 8P+\u003c\/strong\u003e is a premium \u003cstrong\u003eAWS A5.5\/A5.5M E8010-P1\u003c\/strong\u003e cellulosic SMAW electrode specifically engineered for the stringent demands of API 1104 pipeline welding on high-strength line pipe. The \u003cstrong\u003e-P1\u003c\/strong\u003e designator in AWS A5.5 indicates the electrode meets the enhanced toughness (CVN impact) requirements at low temperature that pipeline specifications demand for high-pressure service. Like all Pipeliner-series electrodes, 8P+ runs DC+ only with a fast-freeze, driving arc suited for all-position field welding including the all-critical vertical-down root pass. With 80 ksi minimum tensile strength, it is the choice fill and hot-pass electrode for X65 and higher-grade line pipe where the entire weld joint — not just the root — must meet API toughness requirements. WeldingMart stocks Pipeliner 8P+ as an authorized Lincoln Electric distributor.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"pdp-specs\"\u003e\n  \u003ch2\u003eSpecifications\u003c\/h2\u003e\n  \u003ctable class=\"grade-spec-table\"\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n\u003cth\u003eAWS classification\u003c\/th\u003e\n\u003ctd\u003eAWS A5.5\/A5.5M E8010-P1\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth\u003eCoating type\u003c\/th\u003e\n\u003ctd\u003eCellulosic (high-cellulose sodium), low-hydrogen-compatible formulation\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth\u003ePolarity\u003c\/th\u003e\n\u003ctd\u003eDC+ (DCEP) only\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth\u003eWelding positions\u003c\/th\u003e\n\u003ctd\u003eAll positions: 1G, 2G, 3G, 4G (flat, horizontal, vertical, overhead)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth\u003eMinimum tensile strength\u003c\/th\u003e\n\u003ctd\u003e80,000 psi (551 MPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth\u003eMinimum yield strength\u003c\/th\u003e\n\u003ctd\u003e68,000 psi (469 MPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth\u003eElongation\u003c\/th\u003e\n\u003ctd\u003e19% minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth\u003eCVN impact (-20°F)\u003c\/th\u003e\n\u003ctd\u003eMeets AWS A5.5 -P1 toughness requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth\u003eTypical current range\u003c\/th\u003e\n\u003ctd\u003e3\/32 in: 60–100 A | 1\/8 in: 90–140 A | 5\/32 in: 120–180 A | 3\/16 in: 150–220 A\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth\u003eAvailable diameters\u003c\/th\u003e\n\u003ctd\u003e3\/32, 1\/8, 5\/32, 3\/16 in\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eLincoln Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth\u003eStandards compliance\u003c\/th\u003e\n\u003ctd\u003eAWS A5.5\/A5.5M; API 1104; ASME Section IX\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"pdp-applications\"\u003e\n  \u003ch2\u003eApplications \u0026amp; Industries\u003c\/h2\u003e\n  \u003cp\u003ePipeliner 8P+ is used throughout cross-country pipeline construction and high-pressure oil and gas infrastructure:\u003c\/p\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eAPI 5L X65 and X70 pipeline:\u003c\/strong\u003e Full-bead welding on high-strength line pipe where enhanced low-temperature toughness (-P1) is required by the weld procedure specification\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eHot pass and fill passes:\u003c\/strong\u003e Bridges between the E6010 or E8010 root pass and any low-hydrogen cap passes, maintaining the all-cellulosic procedure where speed is critical\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eOffshore and arctic pipeline:\u003c\/strong\u003e Low-temperature toughness qualification makes 8P+ appropriate for arctic-grade pipeline projects\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMainline girth welds:\u003c\/strong\u003e Consistent mechanical properties for automated inspection (AUT) passes under API 1104 Annex A or B\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCompressor and pump station piping:\u003c\/strong\u003e High-pressure station piping fabrication requiring certified weld procedures\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"pdp-technique\"\u003e\n  \u003ch2\u003eProcess Technology — How to Run Pipeliner 8P+\u003c\/h2\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePower source:\u003c\/strong\u003e CC DC+ engine-driven or inverter (E8010-rated). OCV ≥ 70 V for reliable all-position starts.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eHot pass:\u003c\/strong\u003e Run immediately after root while the joint is still hot (350–500°F) to burn out any root pass gas pockets and fuse the root bead. Increase amperage 10–15% above root pass settings for hot pass.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eFill passes:\u003c\/strong\u003e Use stringer or narrow weave beads; avoid excessive weaving which can introduce lack-of-fusion in the tight pipeline bevel.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eVertical-down progression:\u003c\/strong\u003e Maintain tight arc, 15–20° push angle, controlled travel speed to avoid cold lap. The -P1 formulation supports the higher travel speeds used in production pipeline welding.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePreheat:\u003c\/strong\u003e Follow WPS per base metal CE. X65\/X70 pipe with higher CE typically requires 100–200°F minimum preheat.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eInterpass temperature:\u003c\/strong\u003e Do not exceed maximum interpass temperature specified in WPS — typically 400–500°F for pipeline work.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"pdp-storage\"\u003e\n  \u003ch2\u003eStorage \u0026amp; Handling\u003c\/h2\u003e\n  \u003cp\u003ePipeliner 8P+ is a cellulosic electrode — \u003cstrong\u003edo not store in a drying oven\u003c\/strong\u003e. Cellulosic coatings require inherent moisture; baking will ruin arc performance:\u003c\/p\u003e\n  \u003cul\u003e\n    \u003cli\u003eStore sealed at ambient temperature (40–120°F \/ 4–49°C) in a dry location\u003c\/li\u003e\n    \u003cli\u003eNever bake or oven-dry Pipeliner electrodes — this is for low-hydrogen (E7018, E8018) electrodes only\u003c\/li\u003e\n    \u003cli\u003eRods exposed to rain or excessive humidity should be air-dried only; severely wetted rods should be discarded\u003c\/li\u003e\n    \u003cli\u003eReseal cartons after partial use; protect from jobsite moisture between shifts\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"pdp-faq\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdl\u003e\n    \u003cdt\u003eWhat does the -P1 designation mean on E8010-P1?\u003c\/dt\u003e\n    \u003cdd\u003eThe -P1 suffix in AWS A5.5 designates that the electrode meets supplementary Charpy V-notch (CVN) impact toughness requirements at low temperature, specifically for pipeline applications. API 1104 and certain ASME Section IX procedures require the -P1 toughness classification for high-strength line pipe welding.\u003c\/dd\u003e\n\n    \u003cdt\u003eWhat is Pipeliner 8P+ used for?\u003c\/dt\u003e\n    \u003cdd\u003ePipeliner 8P+ (E8010-P1) is used for hot pass and fill passes on high-strength pipeline (API 5L X65, X70) and for complete-joint welding on line pipe where the entire weld must meet enhanced low-temperature toughness requirements under API 1104 qualified procedures.\u003c\/dd\u003e\n\n    \u003cdt\u003eHow does Pipeliner 8P+ compare to Pipeliner 7P+?\u003c\/dt\u003e\n    \u003cdd\u003eBoth are cellulosic pipeline electrodes in the Pipeliner family. Pipeliner 7P+ (E7010-P1) deposits 70 ksi minimum tensile strength for X52 and X60 pipe applications; Pipeliner 8P+ (E8010-P1) deposits 80 ksi minimum for X65 and X70 pipe. Both include the -P1 toughness qualification. Select based on your WPS minimum tensile requirement.\u003c\/dd\u003e\n\n    \u003cdt\u003eDoes Pipeliner 8P+ require oven storage?\u003c\/dt\u003e\n    \u003cdd\u003eNo. Pipeliner 8P+ is a cellulosic electrode and must not be oven-dried. Store sealed at ambient temperature. Oven storage is only appropriate for low-hydrogen electrodes such as E7018 and E8018.\u003c\/dd\u003e\n\n    \u003cdt\u003eCan I use Pipeliner 8P+ for structural welding (AWS D1.1)?\u003c\/dt\u003e\n    \u003cdd\u003eYes. E8010-P1 is pre-qualified under AWS D1.5 (bridge welding code) and can be procedure-qualified for AWS D1.1 structural applications on higher-strength steels. Confirm the electrode meets your base metal matching requirements per your WPS.\u003c\/dd\u003e\n  \u003c\/dl\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"pdp-crosslinks\"\u003e\n  \u003cp\u003e\u003cstrong\u003eComplete the Pipeliner system:\u003c\/strong\u003e \u003ca href=\"\/collections\/stick-welding-electrodes-rods\"\u003eStick Welding Electrodes \u0026amp; Rods\u003c\/a\u003e — start with \u003ca href=\"\/products\/lincoln-fleetweld-5p-stick-smaw-welding-rod\"\u003eLincoln Fleetweld 5P+ E6010\u003c\/a\u003e for root passes or step up to \u003ca href=\"\/products\/lincoln-pipeliner-7p-stick-smaw-welding-rod\"\u003ePipeliner 7P+ E7010-P1\u003c\/a\u003e for 70 ksi fill passes.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What does the -P1 designation mean on E8010-P1?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The -P1 suffix in AWS A5.5 designates that the electrode meets supplementary Charpy V-notch (CVN) impact toughness requirements at low temperature, specifically for pipeline applications under API 1104 and ASME Section IX.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What is Pipeliner 8P+ used for?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Pipeliner 8P+ (E8010-P1) is used for hot pass and fill passes on high-strength pipeline (API 5L X65, X70) where the entire weld must meet enhanced low-temperature toughness requirements under API 1104 qualified procedures.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How does Pipeliner 8P+ compare to Pipeliner 7P+?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Pipeliner 7P+ (E7010-P1) deposits 70 ksi minimum tensile strength for X52 and X60 pipe; Pipeliner 8P+ (E8010-P1) deposits 80 ksi for X65 and X70 pipe. Both include the -P1 toughness qualification.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does Pipeliner 8P+ require oven storage?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"No. Pipeliner 8P+ is a cellulosic electrode and must not be oven-dried. Store sealed at ambient temperature. Oven storage is only for low-hydrogen electrodes such as E7018 and E8018.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e\n","brand":"Lincoln Electric","offers":[{"title":"1\/8 in · 10 lb Easy Open Can","offer_id":43639137271959,"sku":"ED032615","price":275.7,"currency_code":"USD","in_stock":true},{"title":"1\/8 in · 50 lb Easy Open Can","offer_id":43638076866711,"sku":"ED030826","price":342.3,"currency_code":"USD","in_stock":true},{"title":"5\/32 in · 10 lb Easy Open Can (3-Pack)","offer_id":43639137304727,"sku":"ED032616","price":273.6,"currency_code":"USD","in_stock":true},{"title":"5\/32 in · 50 lb Easy Open Can","offer_id":43638077718679,"sku":"ED030827","price":324.75,"currency_code":"USD","in_stock":true},{"title":"3\/16 in · 10 lb Easy Open Can (3-Pack)","offer_id":43639137403031,"sku":"ED032617","price":277.2,"currency_code":"USD","in_stock":true},{"title":"3\/16 in · 50 lb Easy Open Can","offer_id":43638078177431,"sku":"ED030828","price":340.98,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0628\/7140\/4695\/files\/lincoln-ed032615-pipeliner-8p-stick-smaw-welding-rod-18-14-in-3-10-lb-easy-open-can-lincoln-electric-1.jpg?v=1760720032"},{"product_id":"lincoln-pipeliner-lh-d100-stick-smaw-welding-rod","title":"Lincoln Pipeliner LH-D100 E10045-P2 Stick Welding Rod","description":"\u003c!-- PER-161 Template A parent body | handle lincoln-pipeliner-lh-d100-stick-smaw-welding-rod | bulk render --\u003e\n\u003csection class=\"parent-pdp-intro\"\u003e\n  \u003cp class=\"lead\"\u003e\u003cstrong\u003eLincoln Pipeliner LH-D100\u003c\/strong\u003e is an AWS A5.5\/A5.5M E10045-P2 SMAW stick electrode family with 100 ksi minimum tensile and DC+ only, all positions including vertical-down operation. WeldingMart stocks 2 package and diameter variants of this grade, all sharing the same AWS classification - select the diameter and package format that fits your application below.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection class=\"parent-grade-summary\"\u003e\n  \u003ch2\u003eAbout Lincoln Pipeliner LH-D100\u003c\/h2\u003e\n  \u003cp\u003eE10045-P2 is an AWS A5.5 low-alloy low-hydrogen iron-powder basic-coated SMAW electrode with 100 ksi minimum tensile, classified specifically for pipeline construction (P designator) with vertical-down capability. Engineered for downhill fill and cap passes on the highest-strength API 5L X80 and X100 grade pipe with strict low-hydrogen requirements for sour service and arctic pipeline applications. DC+ in all positions.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection class=\"parent-spec-overview\"\u003e\n  \u003ch2\u003eSpecifications\u003c\/h2\u003e\n  \u003ctable class=\"grade-spec-table\"\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n\u003cth\u003eAWS classification\u003c\/th\u003e\n\u003ctd\u003eAWS A5.5\/A5.5M E10045-P2\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth\u003eMinimum tensile\u003c\/th\u003e\n\u003ctd\u003e100 ksi minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth\u003ePolarity \/ position\u003c\/th\u003e\n\u003ctd\u003eDC+ only, all positions including vertical-down\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth\u003eAvailable diameters\u003c\/th\u003e\n\u003ctd\u003e3\/32 in through 1\/4 in (varies by package)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth\u003ePackage formats\u003c\/th\u003e\n\u003ctd\u003esee size variants below\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/section\u003e\n\u003csection class=\"parent-buy-confidence\"\u003e\n  \u003ch2\u003eWhy buy Lincoln Pipeliner LH-D100 from WeldingMart\u003c\/h2\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBrand-authorized distributor\u003c\/strong\u003e - factory-fresh stock, full warranty pass-through\u003c\/li\u003e\n    \u003cli\u003eMultiple diameter and package variants in stock - select the SKU below that matches your job\u003c\/li\u003e\n    \u003cli\u003eUS warehouse fulfillment, 1 business day ship time\u003c\/li\u003e\n    \u003cli\u003e30-day returns on unopened cartons\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e","brand":"Lincoln Electric","offers":[{"title":"5\/32 in, 10 lb Easy Open Can (3-Pack)","offer_id":43638097739927,"sku":"ED032633","price":428.48,"currency_code":"USD","in_stock":true},{"title":"10 lb Easy Open Can (3-Pack)","offer_id":43638097936535,"sku":"ED032634","price":416.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0628\/7140\/4695\/files\/lincoln-ed032633-pipeliner-lh-d100-stick-smaw-welding-rod-532-14-in-3-10-lb-easy-open-cans-lincoln-electric.jpg?v=1765594688"},{"product_id":"lincoln-pipeliner-lh-d80-stick-smaw-welding-rod","title":"Lincoln Pipeliner LH-D80 E8045-P2 Stick Welding Rod","description":"\u003c!-- PER-161 Template A parent body | handle lincoln-pipeliner-lh-d80-stick-smaw-welding-rod | bulk render --\u003e\n\u003csection class=\"parent-pdp-intro\"\u003e\n  \u003cp class=\"lead\"\u003e\u003cstrong\u003eLincoln Pipeliner LH-D80\u003c\/strong\u003e is an AWS A5.5\/A5.5M E8045-P2 SMAW stick electrode family with 80 ksi minimum tensile and DC+ only, all positions including vertical-down operation. WeldingMart stocks 2 package and diameter variants of this grade, all sharing the same AWS classification - select the diameter and package format that fits your application below.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection class=\"parent-grade-summary\"\u003e\n  \u003ch2\u003eAbout Lincoln Pipeliner LH-D80\u003c\/h2\u003e\n  \u003cp\u003eE8045-P2 is an AWS A5.5 low-alloy low-hydrogen iron-powder basic-coated SMAW electrode with 80 ksi minimum tensile, classified specifically for pipeline construction (P designator) with vertical-down capability (4 in the strength digit). Engineered for downhill fill and cap passes on API 5L X65 and X70 grade pipe where E8010-P1 vertical-down speed is wanted but a low-hydrogen weld is required. DC+ in all positions.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection class=\"parent-spec-overview\"\u003e\n  \u003ch2\u003eSpecifications\u003c\/h2\u003e\n  \u003ctable class=\"grade-spec-table\"\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n\u003cth\u003eAWS classification\u003c\/th\u003e\n\u003ctd\u003eAWS A5.5\/A5.5M E8045-P2\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth\u003eMinimum tensile\u003c\/th\u003e\n\u003ctd\u003e80 ksi minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth\u003ePolarity \/ position\u003c\/th\u003e\n\u003ctd\u003eDC+ only, all positions including vertical-down\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth\u003eAvailable diameters\u003c\/th\u003e\n\u003ctd\u003e3\/32 in through 1\/4 in (varies by package)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth\u003ePackage formats\u003c\/th\u003e\n\u003ctd\u003esee size variants below\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/section\u003e\n\u003csection class=\"parent-buy-confidence\"\u003e\n  \u003ch2\u003eWhy buy Lincoln Pipeliner LH-D80 from WeldingMart\u003c\/h2\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBrand-authorized distributor\u003c\/strong\u003e - factory-fresh stock, full warranty pass-through\u003c\/li\u003e\n    \u003cli\u003eMultiple diameter and package variants in stock - select the SKU below that matches your job\u003c\/li\u003e\n    \u003cli\u003eUS warehouse fulfillment, 1 business day ship time\u003c\/li\u003e\n    \u003cli\u003e30-day returns on unopened cartons\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e","brand":"Lincoln Electric","offers":[{"title":"5\/32 in, 10 lb Easy Open Can (3-Pack)","offer_id":43638092038295,"sku":"ED032627","price":370.81,"currency_code":"USD","in_stock":true},{"title":"10 lb Easy Open Can (3-Pack)","offer_id":43638092890263,"sku":"ED032628","price":359.64,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0628\/7140\/4695\/files\/lincoln-ed032627-pipeliner-lh-d80-stick-smaw-welding-rod-532-14-in-3-10-lb-easy-open-cans-lincoln-electric.jpg?v=1765594806"},{"product_id":"lincoln-pipeliner-lh-d90-stick-smaw-welding-rod","title":"Lincoln Pipeliner LH-D90 E9045-P2 Stick Welding Rod","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eLincoln Electric Pipeliner LH-D90\u003c\/strong\u003e is an AWS A5.5\/A5.5M \u003cstrong\u003eE9045-P2\u003c\/strong\u003e low-hydrogen SMAW stick electrode engineered for demanding pipeline welding applications. Featuring 90 ksi minimum tensile strength and a DC+ only, all-position operating characteristic including \u003cstrong\u003evertical-down\u003c\/strong\u003e capability, the Pipeliner LH-D90 is specifically designed to meet the stringent quality requirements of pipeline field welding, producing X-ray quality welds with superior arc stability and excellent bead profile. WeldingMart is an authorized Lincoln Electric distributor — stock ships from our Wisconsin facility with full manufacturer warranty and certified weld professional support.\u003c\/p\u003e\n\u003cp\u003eRelated products: \u003ca href=\"\/collections\/stick-electrodes-smaw\"\u003eStick Electrodes (SMAW)\u003c\/a\u003e | \u003ca href=\"\/collections\/stick-welding-machines\"\u003eStick Welders\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch2\u003eKey Specifications\u003c\/h2\u003e\n\u003ctable class=\"pdp-spec-table\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003cth scope=\"row\"\u003e\u003cstrong\u003eProcess\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eSMAW (Shielded Metal Arc Welding \/ Stick)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth scope=\"row\"\u003e\u003cstrong\u003eAWS Classification\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eE9045-P2\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth scope=\"row\"\u003e\u003cstrong\u003eElectrode Type\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eLow Hydrogen (LH)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth scope=\"row\"\u003e\u003cstrong\u003eAlloy Class\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eLow Alloy Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth scope=\"row\"\u003e\u003cstrong\u003eMinimum Tensile Strength\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e90 ksi (620 MPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth scope=\"row\"\u003e\u003cstrong\u003ePolarity\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eDCEP (DC+) only\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth scope=\"row\"\u003e\u003cstrong\u003ePositions\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eAll positions including vertical-down\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth scope=\"row\"\u003e\u003cstrong\u003eAvailable Diameters\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e1\/8 in, 5\/32 in\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth scope=\"row\"\u003e\u003cstrong\u003ePackage Size\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e10 lb Easy Open Can (3-Pack)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003cth scope=\"row\"\u003e\u003cstrong\u003eApplication Focus\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003ePipeline welding, vertical-down passes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCross-country pipeline welding:\u003c\/strong\u003e The P2 designation in E9045-P2 confirms qualification for pipeline welding per API 1104 and AWS D10.11 — covering fill and cap passes on high-pressure natural gas and petroleum pipelines.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVertical-down pipeline passes:\u003c\/strong\u003e Pipeliner LH-D90’s fast-freeze slag system supports the vertical-down technique used on transmission pipeline girth welds, where travel speed and bead profile control are critical for productivity and pass geometry.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-strength pipe fabrication:\u003c\/strong\u003e 90 ksi minimum tensile strength makes this electrode appropriate for X65, X70, and similar API 5L high-strength line pipe grades requiring matching or overmatching filler metal.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eField repair and tie-in welds:\u003c\/strong\u003e Compact stick electrode format and wide amperage range enable field use on pipeline repair, hot-tap, and tie-in operations where semi-automatic or GMAW equipment is impractical.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePressure vessel and boiler fabrication:\u003c\/strong\u003e Low hydrogen classification and 90 ksi tensile support use on high-pressure carbon and low-alloy steel vessels where hydrogen cracking risk mitigation is required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eCompatibility — Welders \u0026amp; Equipment\u003c\/h2\u003e\n\u003cp\u003ePipeliner LH-D90 requires a CC (constant current) DC welding power source capable of providing the amperage range appropriate for the selected electrode diameter. Compatible Lincoln Electric platforms include the Vantage, Ranger, and Idealarc engine-driven welders, as well as Invertec and Flextec DC inverter power sources. As a DCEP (DC+) only electrode, ensure your power source output polarity is set to electrode positive before welding. Follow preheat requirements for the applicable base metal and joint configuration per applicable code (API 1104, AWS D1.1) — low hydrogen electrodes require controlled storage (300–350°F \/ 149–177°C holding oven) to maintain low hydrogen content after opening. Reconditioning per the Lincoln Electric rebaking schedule is required for electrodes exposed to humidity.\u003c\/p\u003e\n\n\u003ch2\u003eQuality and Certifications\u003c\/h2\u003e\n\u003cp\u003ePipeliner LH-D90 is classified to \u003cstrong\u003eAWS A5.5\/A5.5M E9045-P2\u003c\/strong\u003e, where the P2 suffix certifies suitability for pipeline welding per the applicable pipeline welding codes. Lincoln Electric manufactures Pipeliner electrodes under ISO 9001-certified processes with full lot traceability. As a low-hydrogen electrode, Pipeliner LH-D90 is formulated and packaged to control moisture absorption — the Easy Open Can hermetically seals the electrodes until opening to maintain certified hydrogen levels in the field. For applications requiring AWS D1.1 or API 1104 compliance, this electrode’s classification satisfies the low-hydrogen requirement.\u003c\/p\u003e\n\n\u003cp\u003e\u003cem\u003e— signed: SEO Silo-chat\u003c\/em\u003e\u003c\/p\u003e","brand":"Lincoln Electric","offers":[{"title":"1\/8 in · 10 lb Easy Open Can (3-Pack)","offer_id":43638094463127,"sku":"ED032629","price":384.48,"currency_code":"USD","in_stock":true},{"title":"5\/32 in · 10 lb Easy Open Can (3-Pack)","offer_id":43638094692503,"sku":"ED032630","price":389.59,"currency_code":"USD","in_stock":true},{"title":"10 lb Easy Open Can (3-Pack)","offer_id":43638095708311,"sku":"ED032631","price":377.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0628\/7140\/4695\/files\/lincoln-ed032629-pipeliner-lh-d90-stick-smaw-welding-rod-18-14-in-3-10-lb-easy-open-cans-lincoln-electric.jpg?v=1765594746"},{"product_id":"lincoln-shield-arc-70-stick-smaw-welding-rod","title":"Lincoln Pipeliner Shield-Arc 70+ E7010-G Stick Welding Rod","description":"\u003c!-- PER-161 Template A parent body | handle lincoln-shield-arc-70-stick-smaw-welding-rod | bulk render --\u003e\n\u003csection class=\"parent-pdp-intro\"\u003e\n  \u003cp class=\"lead\"\u003e\u003cstrong\u003eLincoln Pipeliner Shield-Arc 70+\u003c\/strong\u003e is an AWS A5.5\/A5.5M E7010-G SMAW stick electrode family with 70 ksi minimum tensile and DC+ only, all positions operation. WeldingMart stocks 2 package and diameter variants of this grade, all sharing the same AWS classification - select the diameter and package format that fits your application below.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection class=\"parent-grade-summary\"\u003e\n  \u003ch2\u003eAbout Lincoln Pipeliner Shield-Arc 70+\u003c\/h2\u003e\n  \u003cp\u003eE7010-G is an AWS A5.5 low-alloy cellulosic-coated DC+ SMAW electrode with 70 ksi minimum tensile and a general-classification (G) chemistry agreed between supplier and purchaser. The cellulose coating delivers the deep-penetration, fast-freeze characteristics needed for cross-country pipeline root and fill passes, with low-alloy chemistry tailored to API 5L X-grade pipe applications. DC+ only, all positions.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection class=\"parent-spec-overview\"\u003e\n  \u003ch2\u003eSpecifications\u003c\/h2\u003e\n  \u003ctable class=\"grade-spec-table\"\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n\u003cth\u003eAWS classification\u003c\/th\u003e\n\u003ctd\u003eAWS A5.5\/A5.5M E7010-G\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth\u003eMinimum tensile\u003c\/th\u003e\n\u003ctd\u003e70 ksi minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth\u003ePolarity \/ position\u003c\/th\u003e\n\u003ctd\u003eDC+ only, all positions\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth\u003eAvailable diameters\u003c\/th\u003e\n\u003ctd\u003e3\/32 in through 1\/4 in (varies by package)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth\u003ePackage formats\u003c\/th\u003e\n\u003ctd\u003esee size variants below\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/section\u003e\n\u003csection class=\"parent-buy-confidence\"\u003e\n  \u003ch2\u003eWhy buy Lincoln Pipeliner Shield-Arc 70+ from WeldingMart\u003c\/h2\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBrand-authorized distributor\u003c\/strong\u003e - factory-fresh stock, full warranty pass-through\u003c\/li\u003e\n    \u003cli\u003eMultiple diameter and package variants in stock - select the SKU below that matches your job\u003c\/li\u003e\n    \u003cli\u003eUS warehouse fulfillment, 1 business day ship time\u003c\/li\u003e\n    \u003cli\u003e30-day returns on unopened cartons\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e","brand":"Lincoln Electric","offers":[{"title":"5\/32 in · 50 lb Easy Open Can","offer_id":43638026436759,"sku":"ED012849","price":316.5,"currency_code":"USD","in_stock":false},{"title":"3\/16 in · 50 lb Easy Open Can","offer_id":43638026240151,"sku":"ED012845","price":316.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0628\/7140\/4695\/files\/lincoln-ed012849-shield-arc-70-stick-smaw-welding-rod-532x14-in-50-lb-easy-open-can-lincoln-electric.jpg?v=1765595346"}],"url":"https:\/\/weldingmart.com\/collections\/pipeliner-welding-rods.oembed","provider":"WeldingMart.com","version":"1.0","type":"link"}