| Classification |
Number of layerHardness Rockwell C |
| Typical Result |
1 Layer50-59 |
| Typical Result |
2 Layers50-60 |
| Typical Result, Work-hardened |
1 Layer53-62 |
| Typical Result, Work-hardened |
2 Layers56-62 |
| Typical Result, Flame-hardened |
2 Layers52-54 |
| Typical Result, 180°C (350°F) Interpass Temp |
1 Layer50-55 |
| Typical Result, 180°C (350°F) Interpass Temp |
2 Layers55-59 |
| Classification |
Product Size%Al%C%Cr%Mn%Mo%P%S%Si |
| Typical Result |
.045" (1.1 mm)1.40.455.31.30.80.0100.0040.53 |
| Typical Result |
1/16" (1.6 mm)1.40.455.31.30.80.0100.0040.53 |
| Typical Result |
5/64" (2.0 mm)1.40.455.31.40.80.0100.0040.60 |
| Typical Result |
7/64" (2.8 mm)1.40.455.31.40.80.0100.0040.60 |
| Diameter |
PolarityESO, mm (in.)Wire Feed Speed, m/min (in/min)Voltage, voltsApprox. Current, ampsDeposition Rate, kg/hr (lb/hr) |
| 0.045 in (1.1 mm) |
DC+45 (1 3/4)5.1 (200)25851.6 (3.6) |
| 0.045 in (1.1 mm) |
DC+45 (1 3/4)8.9 (350)281253.0 (6.6) |
| 0.045 in (1.1 mm) |
DC+45 (1 3/4)12.7 (500)311654.3 (9.4) |
| 1/16 in (1.6 mm) |
DC+45 (1 3/4)3.8 (150)261252.2 (4.8) |
| 1/16 in (1.6 mm) |
DC+45 (1 3/4)6.4 (250)291953.8 (8.4) |
| 1/16 in (1.6 mm) |
DC+45 (1 3/4)8.9 (350)322455.5 (12.1) |
| 5/64 in (2.0 mm) |
DC+45 (1 3/4)3.2 (125)241903.2 (7.0) |
| 5/64 in (2.0 mm) |
DC+45 (1 3/4)5.1 (200)272955.0 (11.0) |
| 5/64 in (2.0 mm) |
DC+45 (1 3/4)6.4 (250)303306.2 (13.7) |
| 7/64 in (2.8 mm) |
DC+64 (2 1/2)2.3 (90)252803.8 (8.4) |
| 7/64 in (2.8 mm) |
DC+64 (2 1/2)3.2 (125)273505.2 (11.5) |
| 7/64 in (2.8 mm) |
DC+64 (2 1/2)4.4 (175)304207.3 (16.0) |
| Note |
|
| Cold parts should be warmed to at least 25°C (75°F). Higher preheat of 150 - 260°C (300 - 500°F) may be necessary on thick parts or heavy sections. |
|
| Interpass temperatures between 150°C (300°F) and 200°C (400°F) do not affect the hardness of Lincore® 55 significantly. |
|
| LECO Diameter |
1/16 in (1.6 mm) |
| LECO Package |
25 lb Steel Spool |
| Diameter (in) |
1/16 |