| CONFORMANCES |
SPECIFICATIONCLASSIFICATION |
| AWS |
AWS A5.18ER70S-6 |
| CWB |
CSA W48B-G 49A 3 C1 S6 (B-G 49A 3 C G6) |
| Classification |
Shielding GasPolarityYield Strength @ 0.2% Offset, MPa (ksi)Tensile Strength, MPa (ksi)Elongation, %Charpy V-Notch, J (ft-lbs) @ -30°C (-20°F) |
| ER70S-6 Requirement |
100% CO2DC+400 (58) min.480 (70) min.22 min.27 (20) min. |
| Typical Result, As-welded |
100% CO2DC+470 (68)530-580 (77-84)2656-112 (42-83) |
| Classification |
%C%Cr%Mn%Mo%Ni%P%S%Si%V%Total Cu |
| ER70S-6 Requirement |
0.06 - 0.150.15 max.1.40 - 1.850.15 max.0.15 max.0.025 max.0.035 max.0.80 - 1.150.03 max.0.50 max. |
| Typical Result |
0.07-0.080.021.41-1.490.01 max.0.010.0060.0070.80-0.900.003 max.0.02 |
| Diameter |
Transfer ModeShielding GasPolarityCTWD, mm (in.)⁽¹⁾Wire Feed Speed, m/min (in/min)Voltage, voltsApprox. Current, ampsMelt-off Rate, kg/hr (lb/hr) |
| 0.035 in (0.9 mm) |
Short Circuit Transfer ⁽²⁾100% CO2 DC+9-12 (3/8-1/2)2.5 (100)18800.7 (1.6) |
| 0.035 in (0.9 mm) |
Short Circuit Transfer ⁽²⁾100% CO2 DC+9-12 (3/8-1/2)3.8 (150)191201.1 (2.4) |
| 0.035 in (0.9 mm) |
Short Circuit Transfer ⁽²⁾100% CO2 DC+9-12 (3/8-1/2)6.4 (250)221751.8 (4.0) |
| 0.035 in (0.9 mm) |
Spray Transfer90% Ar / 10% CO2DC+12-19 (1/2-3/4)9.5 (375)231952.7 (6.0) |
| 0.035 in (0.9 mm) |
Spray Transfer90% Ar / 10% CO2DC+12-19 (1/2-3/4)12.7 (500)292303.6 (8.0) |
| 0.035 in (0.9 mm) |
Spray Transfer90% Ar / 10% CO2DC+12-19 (1/2-3/4)15.2 (600)302754.4 (9.6) |
| 0.045 in (1.1 mm) |
Short Circuit Transfer ⁽²⁾100% CO2 DC+12-19 (1/2-3/4)3.2 (125)191451.5 (3.4) |
| 0.045 in (1.1 mm) |
Short Circuit Transfer ⁽²⁾100% CO2 DC+12-19 (1/2-3/4)3.8 (150)201651.8 (4.0) |
| 0.045 in (1.1 mm) |
Short Circuit Transfer ⁽²⁾100% CO2 DC+12-19 (1/2-3/4)5.1 (200)212002.4 (5.4) |
| 0.045 in (1.1 mm) |
Spray Transfer90% Ar / 10% CO2DC+12-19 (1/2-3/4)8.9 (350)272854.2 (9.2) |
| 0.045 in (1.1 mm) |
Spray Transfer90% Ar / 10% CO2DC+12-19 (1/2-3/4)12.1 (475)303355.7 (12.5) |
| 0.045 in (1.1 mm) |
Spray Transfer90% Ar / 10% CO2DC+12-19 (1/2-3/4)12.7 (500)303406.0 (13.2) |
| Note |
|
| ⁽¹⁾ CTWD (Contact Tip to Work Distance). Subtract 1/4 in. (6.4 mm) to calculate Electrical Stickout. |
|
| ⁽²⁾ Procedures in these areas are procedures for short circuiting mode using 100% CO2. When using 75% Argon, 25% CO2 for short circuit transfer, reduce voltage by 1 to 2 volts. |
|
| LECO Diameter |
0.045 in (1.1 mm) |
| LECO Package |
44 lb Spool |
| Diameter (in) |
0.045 |