Call to Talk With A Product Expert - 877-532-WELD (9353)

Lincoln ED031417 SuperArc LA-100 MIG GMAW Mild Steel Welding Wire, 0.045 in, 33 lb Spool

SKU: ED031417
$348.13 $439.23
Lincoln Elite Dealer
Free Shipping
Lowest Price
SuperArc® LA-100™ from Lincoln Electric is a premium copper coated, low alloy MIG welding wire designed for use on 100,000 psi (690 MPa) tensile base material.
AWS / Classification: ER100S-G, ER110S-G

Overview

Lincoln Electric SuperArc® LA-100 is a high-strength low-alloy (HSLA) solid MIG wire classified AWS A5.28 ER100S-G, providing a minimum 100,000 psi tensile strength weld deposit for welding quenched-and-tempered and HSLA steels that demand maximum filler metal strength. This listing is the 0.045" diameter, 33 lb spool (ED031417) — a versatile production format for defense, construction equipment, and structural applications on the highest-strength base metals.

Specifications
Product Line Lincoln Electric SuperArc® LA-100
Part Number ED031417
AWS Classification AWS A5.28 ER100S-G
Wire Diameter 0.045 in (1.14 mm)
Spool / Drum Weight 33 lb Spool
Shielding Gas Required 75% Ar / 25% CO₂ (C25) or 90% Ar / 10% CO₂ (C10)
Polarity DCEP (DC Electrode Positive)
Typical Applications ASTM A514 (T-1 steel), HY-100, HSLA-100, heavy lifting equipment, military vehicles, offshore structural components, and any application requiring 100 ksi minimum tensile weld metal
Recommended Applications

SuperArc LA-100 (AWS A5.28 ER100S-G) is Lincoln's solid wire for the demanding end of the HSLA spectrum. It is the go-to filler for base metals with yield strengths in the 90–110 ksi range, where lower-strength wires would be undermatched per code requirements.

  • ASTM A514 (T-1) fabrication: A514 quenched-and-tempered steel requires matching or over-matching filler metal. ER100S-G is a standard choice for structural and equipment applications on A514 plate.
  • Military and defense: HY-100 and HSLA-100 steels used in armored vehicles, naval vessels, and military structures require high-strength, high-toughness filler metals. LA-100 meets the demanding mechanical property requirements for these applications.
  • Heavy lifting and construction equipment: Crane booms, outrigger pads, excavator arms, and high-strength structural members on mobile cranes and lifting equipment where weight reduction requires higher-strength steel with matching welds.
  • Offshore and subsea structures: High-strength steel components in offshore platforms, topside structures, and subsea manifolds where weld metal strength and CVN toughness are specified at low temperatures.
  • High-strength pressure vessels: ASME Sec. VIII pressure vessels fabricated from high-strength low-alloy materials requiring over-matching filler metal per design code.
Selection Guide

SuperArc LA-100 is the right wire when the base metal minimum tensile strength exceeds approximately 90 ksi, or when the applicable code (AWS D1.1, ASME Sec. IX, MIL-STD) specifies a 100 ksi class filler metal. Do not use LA-100 on standard mild steel (A36, A572 Gr. 50) — the higher alloy content of the wire is unnecessary and may increase sensitivity to hydrogen-induced cracking if preheat procedures are not followed precisely.

If your base metal requires only 90 ksi class filler, SuperArc LA-90 (EDS30776, ER90S-G) is adequate and available in a larger 44 lb spool. For moderate-strength structural work, SuperArc L-56 (ER70S-6) covers A36 and most A572 applications at lower cost.

Browse all Lincoln Electric high-strength and specialty wire options at our MIG Wire collection.

Why Buy from WeldingMart

WeldingMart is an authorized Lincoln Electric distributor. High-strength wire for defense, pressure vessel, and structural applications demands supply chain integrity — every spool of LA-100 must be genuinely manufactured by Lincoln Electric to the chemistry and mechanical property specifications your welding procedure requires.

  • Genuine Lincoln Electric product: Full traceability to Lincoln Electric's quality process. Critical for A514, HY-100, and defense-grade applications where material certification is required.
  • High-strength application expertise: Our team understands the technical requirements of welding quenched-and-tempered and HSLA steels and can help with preheat guidance, shielding gas selection, and code compliance.
  • Fast US shipping: In-stock spools ship promptly to support tight fabrication schedules.
  • Compare options: Browse SuperArc LA-90, LA-100, and the full Lincoln high-strength wire range at our MIG Wire collection.
Specifications
FeatureValue
CONFORMANCES SPECIFICATIONCLASSIFICATION
AWS AWS A5.28 ER100S-G, ER110S-G
ABS ABS - Part 2 4YQ550SA
CWB CWB AWS A5.28 ER69S-G (ER100S-G)
DB ISO 16834-A T 69 5 M21 Mn3Ni1,5Mo
MIL MIL-E-23765/2E MIL-100S-1
MIL T9074-BC-GIB-010/0200 MIL-100S-1
Classification Shielding GasPolarityYield Strength @ 0.2% Offset, MPa (ksi)Tensile Strength, MPa (ksi)Elongation, %Charpy V-Notch, J (ft-lbs) @ -50°C (-60°F)
ER110S-G Requirement Not SpecifiedNot Specified760 (110) min.
Typical Result, As-welded 95% Ar, 5% CO2DC+700 (102)770 (111)21153-175 (113-129)
Typical Result, As-welded 98% Ar, 2% O2DC+740 (107)780-800 (113-116)20149-239 (110-176)
Classification %Al%C%Cr%Mn%Mo%Ni%P%S%Si%Ti%V%Zr%Total Cu
ER110S-G Requirement 0.30 min. *0.20 min. *0.50 min. *
Typical Result 0.010.05-0.060.03-0.041.58-1.670.42-0.451.88-1.990.004-0.0090.003-0.0060.43-0.480.02-0.04<0.005<0.0010.08-0.12
Diameter Transfer ModeShielding GasPolarityCTWD, mm (in.)⁽¹⁾Wire Feed Speed, m/min (in/min)Voltage, voltsApprox. Current, ampsMelt-off Rate, kg/hr (lb/hr)
0.035 in (0.9 mm) Short Circuit Transfer75% Ar / 25% CO2DC+9-12 (3/8-1/2)2.5 (100)18800.7 (1.6)
0.035 in (0.9 mm) Short Circuit Transfer75% Ar / 25% CO2DC+9-12 (3/8-1/2)3.8 (150)191201.1 (2.4)
0.035 in (0.9 mm) Short Circuit Transfer75% Ar / 25% CO2DC+9-12 (3/8-1/2)6.4 (250)221751.8 (4.0)
0.035 in (0.9 mm) Spray Transfer90% Ar / 10% CO2DC+9-12 (3/8-1/2)9.5 (375)231952.7 (6.0)
0.035 in (0.9 mm) Spray Transfer90% Ar / 10% CO2DC+9-12 (3/8-1/2)12.7 (500)292303.6 (8.0)
0.035 in (0.9 mm) Spray Transfer90% Ar / 10% CO2DC+9-12 (3/8-1/2)15.2 (600)302754.4 (9.6)
0.045 in (1.1 mm) Pulsed Spray Transfer ⁽²⁾DC+12-19 (1/2-3/4)5.1 (200)19-211302.4 (5.4)
0.045 in (1.1 mm) Pulsed Spray Transfer ⁽²⁾DC+12-19 (1/2-3/4)6.4 (250)20-231403.0 (6.7)
0.045 in (1.1 mm) Spray Transfer98% Ar / 2% O2DC+12-19 (1/2-3/4)8.9 (350)272854.2 (9.2)
0.045 in (1.1 mm) Spray Transfer98% Ar / 2% O2DC+12-19 (1/2-3/4)12.1 (475)303355.7 (12.5)
0.045 in (1.1 mm) Spray Transfer98% Ar / 2% O2DC+12-19 (1/2-3/4)12.7 (500)303406.0 (13.2)
0.045 in (1.1 mm) Spray Transfer95% Ar / 5% CO2DC+12-19 (1/2-3/4)8.9 (350)272854.2 (9.2)
0.045 in (1.1 mm) Spray Transfer95% Ar / 5% CO2DC+12-19 (1/2-3/4)12.1 (475)303355.7 (12.5)
0.045 in (1.1 mm) Spray Transfer95% Ar / 5% CO2DC+12-19 (1/2-3/4)12.7 (500)303406.0 (13.2)
1/16 in (1.6 mm) Spray Transfer98% Ar / 2% O2DC+12-25 (1/2-1)5.3 (210)253254.8 (10.7)
1/16 in (1.6 mm) Spray Transfer98% Ar / 2% O2DC+12-25 (1/2-1)6.0 (235)273505.4 (12.0)
1/16 in (1.6 mm) Spray Transfer98% Ar / 2% O2DC+12-25 (1/2-1)7.4 (290)284306.7 (14.8)
1/16 in (1.6 mm) Spray Transfer95% Ar / 5% CO2DC+12-25 (1/2-1)5.3 (210)253254.8 (10.7)
1/16 in (1.6 mm) Spray Transfer95% Ar / 5% CO2DC+12-25 (1/2-1)6.0 (235)273505.4 (12.0)
1/16 in (1.6 mm) Spray Transfer95% Ar / 5% CO2DC+12-25 (1/2-1)7.4 (290)284306.7 (14.8)
Note
* To meet the requirements of a "G" classification, the chemical composition of the eletrode must meet the minimum requirement for one or more of
⁽¹⁾ CTWD (Contact Tip to Work Distance). Subtract 1/4 in (6.4 mm) to calculate Electrical Stickout.
⁽²⁾ Procedures in this area are for pulse MIG mode for welding in the vertical up and overhead welding positions. Actual results are dependent on joint, material thickness, as well as wave shape and pulse frequency.
LECO Diameter 0.045 in (1.1 mm)
LECO Package 33 lb Spool
Diameter (in) 0.045
Downloads
Includes
  • (1) 33 lb Spool
Reviews
Q&A