| Classification |
Shielding GasHardness Rockwell C |
| Typical Result |
98% Ar, 2% O256-59 |
| Typical Result |
75% Ar, 25% CO259-61 |
| Classification |
Product SizeNumber of layerShielding Gas%C%Cr%Mn%Mo%Si |
| Typical Result |
.045" (1.1 mm)2 Layers75% Ar, 25% CO20.395.61.20.60.8 |
| Typical Result |
.045" (1.1 mm)2 Layers98% Ar, 2% O20.476.41.40.61.0 |
| Typical Result |
1/16" (1.6 mm)2 Layers75% Ar, 25% CO20.415.31.20.60.8 |
| Typical Result |
1/16" (1.6 mm)2 Layers98% Ar, 2% O20.455.51.20.61.0 |
| Diameter |
Shielding GasPolarityESO, mm (in.)Wire Feed Speed, m/min (in/min)Voltage, voltsApprox. Current, ampsDeposition Rate, kg/hr (lb/hr) |
| 0.045 in (1.1 mm) |
75% Ar / 25% CO2DC+16 (5/8)5.1 (200)271652.0 (4.3) |
| 0.045 in (1.1 mm) |
75% Ar / 25% CO2DC+16 (5/8)7.6 (300)292253.0 (6.7) |
| 0.045 in (1.1 mm) |
75% Ar / 25% CO2DC+16 (5/8)10.2 (400)312904.2 (9.2) |
| 0.045 in (1.1 mm) |
90% Ar / 10% CO2DC+20 (3/4)5.1 (200)251452.1 (4.7) |
| 0.045 in (1.1 mm) |
90% Ar / 10% CO2DC+20 (3/4)7.6 (300)281953.3 (7.2) |
| 0.045 in (1.1 mm) |
90% Ar / 10% CO2DC+20 (3/4)10.2 (400)302454.4 (9.7) |
| 0.045 in (1.1 mm) |
98% Ar / 2% O2DC+20 (3/4)5.1 (200)251452.3 (5.1) |
| 0.045 in (1.1 mm) |
98% Ar / 2% O2DC+20 (3/4)7.6 (300)272003.4 (7.5) |
| 0.045 in (1.1 mm) |
98% Ar / 2% O2DC+20 (3/4)8.9 (350)282253.9 (8.7) |
| 0.045 in (1.1 mm) |
98% Ar / 2% O2DC+20 (3/4)10.2 (400)292504.4 (9.8) |
| 1/16 in (1.6 mm) |
75% Ar / 25% CO2DC+20 (3/4)3.8 (150)282602.6 (5.8) |
| 1/16 in (1.6 mm) |
75% Ar / 25% CO2DC+20 (3/4)6.4 (250)303404.7 (10.4) |
| 1/16 in (1.6 mm) |
75% Ar / 25% CO2DC+20 (3/4)8.9 (350)324206.8 (15.1) |
| 1/16 in (1.6 mm) |
90% Ar / 10% CO2DC+20 (3/4)3.8 (150)252302.7 (6.0) |
| 1/16 in (1.6 mm) |
90% Ar / 10% CO2DC+20 (3/4)6.4 (250)273154.9 (10.7) |
| 1/16 in (1.6 mm) |
90% Ar / 10% CO2DC+20 (3/4)8.9 (350)294007.0 (15.4) |
| 1/16 in (1.6 mm) |
98% Ar / 2% O2DC+20 (3/4)3.8 (150)242202.9 (6.4) |
| 1/16 in (1.6 mm) |
98% Ar / 2% O2DC+20 (3/4)6.4 (250)263155.0 (11.0) |
| 1/16 in (1.6 mm) |
98% Ar / 2% O2DC+20 (3/4)8.9 (350)284107.1 (15.7) |
| Note |
|
| Interpass temperatures between 150°C (300°F) and 200°C (400°F) do not affect the hardness of Lincore® 55 significantly. |
|
| LECO Diameter |
0.045 in (1.1 mm) |
| LECO Package |
500 lb Accu-Trak® Drum |
| Diameter (in) |
0.045 |