| CONFORMANCES |
SPECIFICATIONCLASSIFICATION |
| AWS |
AWS A5.20E71T-1C-H8, E71T-9C-H8 |
| AWS |
AWS A5.36E71T1-C1A2-CS1-H8 |
| ABS |
ABS - Part 22Y400SA H10, 2YSA H10 |
| BV |
BV - Chapter 5SA2Y H10 |
| DNV-GL |
DNV - 2.9II YMS H10 |
| LR |
LR - Chapter 112YS H10 |
| Classification |
Shielding GasPolarityYield Strength @ 0.2% Offset, MPa (ksi)Tensile Strength, MPa (ksi)Elongation, %Charpy V-Notch, J (ft-lbs) @ -30°C (-20°F) |
| E71T-1C-H8 Requirement |
100% CO2DC+400 (58) min.480-660 (70-95)22 min. |
| E71T-9C-H8 Requirement |
100% CO2DC+400 (58) min.480-660 (70-95)22 min.27 (20) min. |
| E71T1-C1A2-CS1-H8 Requirement |
100% CO2DC+400 (58) min.480-660 (70-95)22 min.27 (20) min. |
| Typical Result, As-welded |
100% CO2DC+490 (71)560-660 (81-95)2535-127 (26-94) |
| Classification |
Shielding GasPolarity%B%C%Mn%P%S%SiDiffusible Hydrogen, mL/100g Weld Metal |
| E71T-1C-H8 Requirement |
100% CO2DC+0.12 max.1.75 max.0.03 max.0.03 max.0.90 max.8.0 max. |
| E71T-9C-H8 Requirement |
100% CO2DC+0.12 max.1.75 max.0.03 max.0.03 max.0.90 max.8.0 max. |
| E71T1-C1A2-CS1-H8 Requirement |
100% CO2DC+0.12 max.1.75 max.0.030 max.0.030 max.0.90 max.8 max. |
| Typical Result |
100% CO2DC+0.0030-0.00420.05-0.061.39-1.700.01-0.020.006-0.010.35-0.402.6-6 |
| Diameter |
Shielding GasPolarityCTWD, mm (in.)⁽¹⁾Wire Feed Speed, m/min (in/min)Voltage, voltsApprox. Current, ampsMelt-off Rate, kg/hr (lb/hr)Deposition Rate, kg/hr (lb/hr)Efficiency, % |
| 0.052 in (1.3 mm) |
100% CO2DC+19-25 (3/4-1)3.8 (150)22-251402.0 (4.5)1.7 (3.7)81-85 |
| 0.052 in (1.3 mm) |
100% CO2DC+19-25 (3/4-1)5.1 (200)23-261752.6 (5.8)2.2 (4.9)81-85 |
| 0.052 in (1.3 mm) |
100% CO2DC+19-25 (3/4-1)6.4 (250)23-272103.4 (7.4)2.8 (6.2)81-85 |
| 0.052 in (1.3 mm) |
100% CO2DC+19-25 (3/4-1)7.6 (300)24-292304.0 (8.8)3.4 (7.4)81-85 |
| 0.052 in (1.3 mm) |
100% CO2DC+19-25 (3/4-1)8.9 (350)26-302554.6 (10.2)3.9 (8.7)81-85 |
| 0.052 in (1.3 mm) |
100% CO2DC+19-25 (3/4-1)9.5 (375)27-302755.0 (11.1)4.3 (9.4)81-85 |
| 0.052 in (1.3 mm) |
100% CO2DC+19-25 (3/4-1)10.2 (400)29-312805.4 (11.9)4.5 (9.9)81-85 |
| 0.052 in (1.3 mm) |
100% CO2DC+19-25 (3/4-1)12.1 (475)29-332956.5 (14.3)5.5 (12.2)81-85 |
| 0.052 in (1.3 mm) |
100% CO2DC+19-25 (3/4-1)12.7 (500)30-343207.0 (15.4)5.8 (12.8)81-85 |
| 1/16 in (1.6 mm) |
100% CO2DC+19-25 (3/4-1)3.8 (150)23-261852.9 (6.3)2.4 (5.3)83-87 |
| 1/16 in (1.6 mm) |
100% CO2DC+19-25 (3/4-1)4.4 (175)23-272203.3 (7.3)2.8 (6.1)83-87 |
| 1/16 in (1.6 mm) |
100% CO2DC+19-25 (3/4-1)5.1 (200)23-272403.8 (8.3)3.2 (7.1)83-87 |
| 1/16 in (1.6 mm) |
100% CO2DC+19-25 (3/4-1)5.7 (225)23-282604.2 (9.2)3.7 (8.2)83-87 |
| 1/16 in (1.6 mm) |
100% CO2DC+19-25 (3/4-1)6.4 (250)24-292754.7 (10.4)4.3 (9.4)83-87 |
| 1/16 in (1.6 mm) |
100% CO2DC+19-25 (3/4-1)7.6 (300)25-303155.6 (12.4)4.8 (10.6)83-87 |
| 1/16 in (1.6 mm) |
100% CO2DC+19-25 (3/4-1)8.3 (325)27-313256.1 (13.5)5.3 (11.7)83-87 |
| 1/16 in (1.6 mm) |
100% CO2DC+19-25 (3/4-1)8.9 (350)27-313356.7 (14.7)5.8 (12.7)83-87 |
| 1/16 in (1.6 mm) |
100% CO2DC+19-25 (3/4-1)9.5 (400)28-323607.7 (16.9)6.6 (14.5)83-87 |
| Note |
|
| ⁽¹⁾ To estimate ESO, subtract 1/4 in. (6.0 mm) from CTWD. |
|
| LECO Diameter |
0.052 in (1.3 mm) |
| LECO Package |
33 lb Spool |
| Diameter (in) |
0.052 |