Call to Talk With A Product Expert - 877-532-WELD (9353)

Used Lincoln Ranger 250 GXT — Low Hour Factory Demo Engine Driven Welder Kohler W/EFP - U2382-4

SKU: U2382-4
$7,199.00 $8,829.99
Full New Factory Warranty Same warranty as a brand-new unit — backed by Lincoln Electric.

Financing Options

•
As low as …/mo with.
•
Loading Affirm Estimate…
Lincoln Elite Dealer
Lowest Price
The Lincoln Ranger 250 GXT - U2382-4 Engine Driven Welder offers 250 amps of AC/DC welding power and 11,000 watts peak generator output. Powered by a 23 HP Kohler engine, it includes a fully enclosed case, remote readiness, and is built for rugged reliability.

Overview
Downloads & Documentation
Lincoln Ranger 250 GXT — Factory Demo Engine Driven Welder (U2382-4)

The Ranger 250 GXT features a totally enclosed case design that fully protects the engine with three service access doors for easy maintenance. It operates with impressively low noise levels - just 76.4 dBA sound level at 23 ft. (7 m) and 100.7 dB sound power (Lwa) at rated output, making it ideal for noise-sensitive work environments. Customers can choose from painted, camo wrapped, or stainless steel roof, case sides and engine doors to match their specific application requirements. The versatile AC/DC welding output accommodates a broad range of stick electrode types, while providing excellent AC TIG welding capabilities with the optional TIG Module and either a foot or hand Amptrol for aluminum and other alloy welding. The unit is also MIG and Flux-Cored capable with optional equipment, and includes a 6-pin connector and local/remote switch for convenient remote control operation.

Get all of the XTras needed for construction and maintenance work. That's XTra welding performance with 250 amps for AC or DC stick and DC wire welding and XTra power with up to 11,000 watts peak for lights, grinders or high amperage equipment. You also get XTra protection and quiet operation with the Lincoln enclosed case.

Powered by a robust 23 HP Kohler gasoline engine, this unit features a 2 cylinder, 4 cycle overhead valve air-cooled design with an electric fuel pump that effectively prevents vapor lock issues. The engine includes an oil drain extension for easy maintenance and a generous 12 gallon tank for extended run times. The electric fuel gauge conveniently located on the control panel makes it easy to check fuel levels during operation and refueling. With 11,000 watts peak single-phase AC generator power and 10,000 watts continuous power, the Ranger 250 GXT can efficiently run generators, plasma cutters, inverter welders, lights, grinders, and various power tools. Built for rugged reliability in demanding environments, both the welding and AC generator outputs are rated for performance at 104°F (40°C), ensuring dependable operation even in extreme conditions.

Key Features
  • Totally Enclosed Case with three service access doors and low noise operation
  • Versatile AC/DC Welding for a broad range of stick electrode types and excellent AC TIG capabilities
  • 11,000 Watts Peak Single-Phase AC Generator Power with 10,000 watts continuous
  • 23 HP Kohler Gasoline Engine with electric fuel pump and 12 gallon tank
Specifications
Product Weights & Dimensions
Dimensions (H x W x D) 30 in x 21.5 in x 42.3 in (762 mm x 546 mm x 1073 mm)
Net Weight 602 lbs (273 kg)

General Specification
Machines Processes Stick (SMAW)
TIG (GTAW)
MIG (GMAW)
Flux-Cored Self-Shielded (FCAW-S)
Flux-Cored Gas-Shielded (FCAW-G)

Machine Technologies & Connections
Output Range by Mode CC-Stick: 50 – 250 Amps, CV-Wire: 14 – 28 Volts

Engine Driven Welders
Single Phase Auxiliary Output 10,000 Watts Continuous, 120/240V
Auxiliary Output Frequency 60 Hz
Receptacle Types NEMA 5-20R
NEMA 14-50R
Engine Brand & Model Kohler OHV Command CH730
Engine Description 2 Cylinder Air-Cooled Gasoline Engine
Engine Horsepower 23 HP
High Idle Operating Speed @ Rated Output 3600
Fuel Tank Size (US gal.) 12
Fuel Tank Size (L) 45.4
Oil Capacity (qts.) 2.0
Oil Capacity (L) 1.9

Application
Typical Application Construction
Construction & Field Erection
General Fabrication
Maintenance & Repair
Repair Welding
Structural Fabrication
Structural Welding

Warranty
Warranty 3 Years Parts and Labor - Engine warranted separately by engine manufacturer
Frequently Asked Questions
What welding processes does the Ranger 250 GXT support?

Lincoln lists the welding processes for the Ranger 250 GXT as: Stick, TIG, MIG, Flux-Cored, Gouging. Source: Lincoln spec sheet E6.96.

Does the Ranger 250 GXT have a generator output for powering tools?

Yes. Lincoln publishes the auxiliary AC generator output for the Ranger 250 GXT as: single-phase 11,000 Watts Peak / 10,000 Watts Continuous (60 Hz Single Phase). Lincoln publishes these receptacles for this machine:

  • Two 120V Duplex Receptacles — 120V, 20A per Duplex, 40A Total, NEMA 5-20R
  • 120V/240V Receptacle (Full KVA) — 120V/240V, 42A Each 120V Branch; 42A @ 240V, NEMA 14-50R

Source: Lincoln spec sheet E6.96.

What engine powers the Ranger 250 GXT?

The Ranger 250 GXT on this listing is powered by a Kohler Command 23 HP CH730 OHV gasoline engine, 23 HP. Kohler engines in this line are gasoline or LP-Gas — there is no Kohler diesel in the Lincoln engine-drive range. Lincoln’s current engine-warranty document brands Kohler as Rehlko (formerly Kohler). Source: Lincoln spec sheet E6.96.

What is the duty cycle rating?

Duty cycle varies by output setting. On the Ranger 250 GXT every rated welding output Lincoln publishes is 100% duty cycle — 250 A / 25 V in AC CC, DC CC and DC CV — with Lincoln stating “all rated outputs at 100% duty cycle 104°F (40°C).”

Rated welding output and duty cycle — Ranger 250 GXT (K2382-4), Lincoln spec sheet E6.96
Welding process / output mode Rating basis Amperes Volts Duty cycle As printed by Lincoln
AC Constant Current NOT LABELLED (CC Rated Output column) 250A 25V 100% 250A/25V/100%
DC Constant Current NOT LABELLED (CC Rated Output column) 250A 25V 100% 250A/25V/100%
DC Constant Voltage NOT LABELLED (CV-Rated Output column) 250A 25V 100% 250A/25V/100%
Output range — as printed by Lincoln
Mode / parameter Range
Current Ranges (CC) 160-250A / 110-180A / 70-130A / 50-80A
Output Range (Product Specifications table) 50-250A AC/DC
CV voltage ranges 14-22V and 18-28V (Machine Specifications); 14-28V CV (Product Specifications)
Open circuit voltage Max OCV @ 3700 RPM 80V RMS
Rated ambient temperature "All rated outputs at 100% duty cycle 104°F (40°C)." / "Welding and AC Generator Outputs Rated at 104°F (40°C)"
Auxiliary (AC generator) power — Ranger 250 GXT (K2382-4), Lincoln spec sheet E6.96
Specification As printed by Lincoln
Peak / surge output 11,000 Watts Peak
Continuous output 10,000 Watts Continuous
Single-phase 11,000 Watts Peak / 10,000 Watts Continuous
Three-phase NONE PRESENT (single-phase machine)
Frequency / phase 60 Hz Single Phase
Auxiliary receptacles — as printed by Lincoln
Receptacle Voltage Amperage NEMA type
Two 120V Duplex Receptacles 120V 20A per Duplex, 40A Total NEMA 5-20R
120V/240V Receptacle (Full KVA) 120V/240V 42A Each 120V Branch; 42A @ 240V NEMA 14-50R

Source: Lincoln Electric publication E6.96 (Issue Date 01/21) — view the Lincoln spec sheet PDF. Figures are Lincoln's own; “NOT STATED” means Lincoln does not publish that value for this machine.

Is this a factory demo or refurbished unit?

Yes — this is a factory demo or low-hour unit directly from Lincoln Electric. Units may show light cosmetic marks from display use but are mechanically sound. The warranty on this unit is the same as on a new machine. Lincoln’s Industrial Limited Warranty (form IMWS1, Apr-2026) lists a 3-year warranty period for “All Lincoln welding machines, wirefeeders & plasma cutting machines”, and Lincoln states: “Lincoln will assume both the parts and labor expense of correcting defects during the warranty period.” As on a new machine, the engine is not covered by Lincoln’s warranty — Lincoln states: “All engines and engine accessories are warranted by the engine or engine accessory manufacturer and are not covered by this warranty.” This machine’s Kohler Command 23 HP CH730 OHV engine is warranted by Rehlko (formerly Kohler): “Three Years”, and that term “BEGINS ON DATE OF PURCHASE BY END USER.” Lincoln footnotes the Rehlko (formerly Kohler) three-year term “First owner only.” Lincoln directs buyers to the engine maker — WWW.ENGINES.REHLKO.COM / 1-800-544-2444 Rehlko Service Department. See Lincoln Engine Drive Motors Warranty Contacts. Source: Lincoln Electric Industrial Limited Warranty (form IMWS1, Apr-2026).

What does this unit come with?

Lincoln’s own included-items list for K2382-4 is: (1) Ranger 250 GXT Engine Driven Welder (Lincoln K2382-4). This factory demo unit is supplied the same way. Not included: welding leads (electrode and work cable), electrode holder, work clamp, and accessory kits. No printed operator’s manual, WeldingMart demo-prep certification document or Lincoln warranty registration paperwork ships with the machine. Consumables (electrodes, gas cylinders) are not included. Leads, holders, clamps, cable connectors, undercarriages, spark arrestors, remote controls and wire feeders are sold separately — contact WeldingMart and we will quote the exact set you need.

Reviews
Q&A